Related Experiment Video
Updated: May 22, 2026

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
Development and evaluation of TWIST Dixon for dynamic contrast-enhanced (DCE) MRI with improved acquisition
Yuan Le1, Randall Kroeker, Hal D Kipfer
1Department of Radiology and Imaging Science, Indiana University School of Medicine, Indianapolis, IN 46202, USA.
Purpose:
To develop a new pulse sequence called time-resolved angiography with stochastic trajectories (TWIST) Dixon for dynamic contrast enhanced magnetic resonance imaging (DCE-MRI).
Materials And Methods:
The method combines dual-echo Dixon to generate separated water and fat images with a k-space view-sharing scheme developed for 3D TWIST. The performance of TWIST Dixon was compared with a volume interpolated breathhold examination (VIBE) sequence paired with spectrally selective adiabatic inversion Recovery (SPAIR) and quick fat-sat (QFS) fat-suppression techniques at 3.0T using quantitative measurements of fat-suppression accuracy and signal-to-noise ratio (SNR) efficiency, as well as qualitative breast image evaluations.
Results:
The water fraction of a uniform phantom was calculated from the following images: 0.66 ± 0.03 for TWIST Dixon; 0.56 ± 0.23 for VIBE-SPAIR, and 0.53 ± 0.14 for VIBE-QFS, while the reference value is 0.70 measured by spectroscopy. For phantoms with contrast (Gd-BOPTA) concentration ranging from 0-6 mM, TWIST Dixon also provides consistently higher SNR efficiency (3.2-18.9) compared with VIBE-SPAIR (2.8-16.8) and VIBE-QFS (2.4-12.5). Breast images acquired with TWIST Dixon at 3.0T show more robust and uniform fat suppression and superior overall image quality compared with VIBE-SPAIR.
Conclusion:
The results from phantom and volunteer evaluation suggest that TWIST Dixon outperforms conventional methods in almost every aspect and it is a promising method for DCE-MRI and contrast-enhanced perfusion MRI, especially at higher field strength where fat suppression is challenging.
More Related Videos
05:37A 3D Quantification Technique for Liver Fat Fraction Distribution Analysis Using Dixon Magnetic Resonance Imaging
Published on: October 20, 2023
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System IV: CMRI