Related Experiment Video
Updated: May 22, 2026

Utilizing Percutaneous Ventricular Assist Devices in Acute Myocardial Infarction Complicated by Cardiogenic Shock
Published on: June 12, 2021
Use of Impella 5L for acute allograft rejection postcardiac transplant
Rahul Chandola1, Robert Cusimano, Mark Osten
1Division of Cardiovascular Surgery, Toronto General Hospital, 200 Elizabeth Street, Toronto, Ontario, Canada. r_chandola@rediffmail.com
Abstract:
The contribution of acute allograft rejection to posttransplant mortality has decreased over time primarily due to improvements in maintenance immunosuppression and in the diagnosis and treatment of rejection. Nevertheless, acute heart allograft rejection remains an important clinical problem.2 In the setting of an acute allograft rejection, mechanical circulatory support has been provided by a variety of devices, ranging from intra-aortic balloon pumps (IABP) to extracorporeal membrane oxygenators (ECMO), left ventricular assist devices (LVADs) and biventricular assist devices (BIVADs).2 We present a 45-year-old patient with cardiogenic shock secondary to acute allograft rejection after orthotopic heart transplantation. Patient continued to have poor hemodynamics and low cardiac output despite being on high doses of inotropes and an aggressive immunosuppression. Hence, a decision was made to support the hemodynamics with an Impella LP 5.0 (Abiomed Inc, Danvers, MA) left ventricular assist device (LVAD).