Related Experiment Video
Updated: May 22, 2026

A Modified Sonographic Algorithm for Image Acquisition in Life-Threatening Emergencies in the Critically Ill Newborn
Published on: April 7, 2023
Pulse oximetry screening for critical congenital heart defects in asymptomatic newborn babies: a systematic review
Shakila Thangaratinam1, Kiritrea Brown2, Javier Zamora3
1Women's Health Research Unit, Centre for Primary Care and Public Health, Barts and the London School of Medicine and Dentistry, Queen Mary University of London, London, UK.
Insights
Pulse oximetry effectively screens newborn babies for critical congenital heart defects. This method demonstrates high specificity and moderate sensitivity, supporting its use in universal newborn screening programs.
Area of Science:
- Neonatal Medicine
- Cardiology
- Diagnostic Screening
Background:
- Critical congenital heart defects (CCHDs) require early detection for improved infant outcomes.
- Pulse oximetry is a non-invasive method to assess oxygen saturation in newborns.
- Screening asymptomatic newborns can identify CCHDs before clinical manifestation.
Purpose of the Study:
- To evaluate the performance of pulse oximetry in detecting critical congenital heart defects in asymptomatic newborns.
- To systematically review existing evidence on the accuracy of pulse oximetry for CCHD screening.
Main Methods:
- Systematic review of studies published between 1951 and 2011, searching Medline, Embase, Cochrane Library, and Scisearch.
- Inclusion criteria focused on studies assessing pulse oximetry accuracy for CCHDs in asymptomatic newborns.
- Data extraction included sensitivity, specificity, and false-positive rates; analysis employed a hierarchical receiver operating characteristic curve with a random effects model.
Main Results:
- Analysis of 13 studies involving 229,421 newborns.
- Overall sensitivity for pulse oximetry was 76.5% (95% CI 67.7-83.5).
- Exceptional specificity of 99.9% (99.7-99.9) and a low false-positive rate of 0.14% (0.06-0.33) were observed. Screening after 24 hours of birth yielded a significantly lower false-positive rate (0.05%) compared to before 24 hours (0.50%).
Conclusions:
- Pulse oximetry is a highly specific screening tool for critical congenital heart defects in newborns.
- The test demonstrates moderate sensitivity, meeting established criteria for universal screening.
- Timing of pulse oximetry screening (after 24 hours) can optimize its performance by reducing false positives.
Background:
Screening for critical congenital heart defects in newborn babies can aid in early recognition, with the prospect of improved outcome. We assessed the performance of pulse oximetry as a screening method for the detection of critical congenital heart defects in asymptomatic newborn babies.
Methods:
In this systematic review, we searched Medline (1951-2011), Embase (1974-2011), Cochrane Library (2011), and Scisearch (1974-2011) for relevant citations with no language restriction. We selected studies that assessed the accuracy of pulse oximetry for the detection of critical congenital heart defects in asymptomatic newborn babies. Two reviewers selected studies that met the predefined criteria for population, tests, and outcomes. We calculated sensitivity, specificity, and corresponding 95% CIs for individual studies. A hierarchical receiver operating characteristic curve was fitted to generate summary estimates of sensitivity and specificity with a random effects model.
Findings:
We screened 552 studies and identified 13 eligible studies with data for 229,421 newborn babies. The overall sensitivity of pulse oximetry for detection of critical congenital heart defects was 76·5% (95% CI 67·7-83·5). The specificity was 99·9% (99·7-99·9), with a false-positive rate of 0·14% (0·06-0·33). The false-positive rate for detection of critical congenital heart defects was particularly low when newborn pulse oximetry was done after 24 h from birth than when it was done before 24 h (0·05% [0·02-0·12] vs 0·50 [0·29-0·86]; p=0·0017).
Interpretation:
Pulse oximetry is highly specific for detection of critical congenital heart defects with moderate sensitivity, that meets criteria for universal screening.
Funding:
None.
More Related Videos
07:51Standardized Hemorrhagic Shock Induction Guided by Cerebral Oximetry and Extended Hemodynamic Monitoring in Pigs
Published on: May 21, 2019
10:55A Piglet Perinatal Asphyxia Model to Study Cardiac Injury and Hemodynamics after Cardiac Arrest, Resuscitation, and the Return of Spontaneous Circulation
Published on: January 13, 2023
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Measurement of Blood Pressure