Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Video

Updated: May 22, 2026

Fluorescent Lateral Flow Immunoassay Based on Quantum Dots Nanobeads
07:13

Fluorescent Lateral Flow Immunoassay Based on Quantum Dots Nanobeads

Published on: June 28, 2024

Quantum dot based rapid tests for zearalenone detection.

N V Beloglazova1, E S Speranskaya, S De Saeger

  • 1Faculty of Pharmaceutical Sciences, Laboratory of Food Analysis, Ghent University, Belgium.

Analytical and Bioanalytical Chemistry
|May 5, 2012
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Preparation and characterization of stable phospholipid-silica nanostructures loaded with quantum dots.

Journal of materials chemistry. B·2020
Same author

Luminescent quantum dots for miRNA detection.

Talanta·2018
Same author

Lanthanide-to-quantum dot Förster resonance energy transfer (FRET): Application for immunoassay.

Talanta·2017
Same author

Sensitive immunochemical approaches for quantitative (FPIA) and qualitative (lateral flow tests) determination of gentamicin in milk.

Talanta·2016
Same author

Rapid screening of aflatoxin B1 in beer by fluorescence polarization immunoassay.

Talanta·2015
Same author

Silica-coated liposomes loaded with quantum dots as labels for multiplex fluorescent immunoassay.

Talanta·2015
Same journal

Analyses of dextroamphetamine and its metabolites in human urine by capillary electrophoresis with diode array and capacitively coupled contactless conductivity detection (CE-DAD-C<sup>4</sup>D).

Analytical and bioanalytical chemistry·2026
Same journal

Whole-body mass spectrometry imaging reveals metabolome and lipid peroxidation heterogeneity in zebrafish xenografts of esophageal squamous cell carcinoma.

Analytical and bioanalytical chemistry·2026
Same journal

A robust and validated method for the determination of 21 urinary metabolites of 15 plasticizers, including phthalates, DEHTP, and DINCH, by online SPE and liquid chromatography-tandem mass spectrometry.

Analytical and bioanalytical chemistry·2026
Same journal

A label-free membrane-based biosensor array with AuNP-modified PDMS for sensitive and specific detection of alpha-fetoprotein.

Analytical and bioanalytical chemistry·2026
Same journal

Smartphone-integrated one-step colorimetric glucose detection at physiological pH enabled by a haloperoxidase mimic.

Analytical and bioanalytical chemistry·2026
Same journal

Chemiluminescence functionalized magnetic nanoparticles-based biosensor for sensitive detection of glucose, uric acid, and cholesterol.

Analytical and bioanalytical chemistry·2026
See all related articles

Quantum dots (QDs) enhance luminescence-based immunosorbent assays for zearalenone (ZEN) detection. These assays offer improved sensitivity and are suitable for analyzing ZEN in complex food matrices, even at very low levels.

Area of Science:

  • * Analytical Chemistry
  • * Biotechnology
  • * Food Safety

Background:

  • * Zearalenone (ZEN) is a toxic metabolite produced by Fusarium fungi, posing a risk to food safety.
  • * Accurate and sensitive detection methods are crucial for monitoring ZEN levels in food products.
  • * Traditional enzyme-labeled immunosorbent assays can be limited in sensitivity and performance.

Purpose of the Study:

  • * To develop and compare three novel luminescence-based immunosorbent assays for zearalenone (ZEN) determination.
  • * To evaluate the use of cadmium selenide/zinc sulfide (CdSe/ZnS) core/shell quantum dots (QDs) as labels.
  • * To assess the suitability of QD-labeled assays for analyzing ZEN in complex food matrices.

Main Methods:

  • * Development of a fluorescent-labeled immunosorbent assay (FLISA) using QD labels.

More Related Videos

Rapid Detection of Helicobacter pylori Virulence and Typing Using Quantum Dot Labeling Technology
05:13

Rapid Detection of Helicobacter pylori Virulence and Typing Using Quantum Dot Labeling Technology

Published on: June 13, 2025

Development of a Lateral Flow Immunochromatographic Strip for Rapid and Quantitative Detection of Small Molecule Compounds
10:10

Development of a Lateral Flow Immunochromatographic Strip for Rapid and Quantitative Detection of Small Molecule Compounds

Published on: November 13, 2021

Related Experiment Videos

Last Updated: May 22, 2026

Fluorescent Lateral Flow Immunoassay Based on Quantum Dots Nanobeads
07:13

Fluorescent Lateral Flow Immunoassay Based on Quantum Dots Nanobeads

Published on: June 28, 2024

Rapid Detection of Helicobacter pylori Virulence and Typing Using Quantum Dot Labeling Technology
05:13

Rapid Detection of Helicobacter pylori Virulence and Typing Using Quantum Dot Labeling Technology

Published on: June 13, 2025

Development of a Lateral Flow Immunochromatographic Strip for Rapid and Quantitative Detection of Small Molecule Compounds
10:10

Development of a Lateral Flow Immunochromatographic Strip for Rapid and Quantitative Detection of Small Molecule Compounds

Published on: November 13, 2021

  • * Creation of two qualitative QD-based column test methods using sepharose gel and polyethylene frits for antibody immobilization.
  • * Comparison of QD-labeled assays against traditional enzyme-labeled assays and liquid chromatography-tandem mass spectrometry (LC-MS/MS) for validation.
  • Main Results:

    • * QD-labeled FLISA demonstrated a fourfold decrease in IC50 value (0.1 ng mL(-1)) and a lower detection limit (0.03 ng mL(-1)) compared to traditional assays.
    • * Qualitative column tests established cutoff levels of 5 ng mL(-1) for ZEN detection, considering regulatory limits.
    • * Assays were successfully applied to raw wheat samples, showing good performance even with high sample extract dilution.

    Conclusions:

    • * Quantum dots significantly enhance the sensitivity of luminescence-based immunosorbent assays for zearalenone detection.
    • * QD-labeled FLISA and column tests are effective tools for analyzing ZEN in complex food matrices at low concentrations.
    • * These developed methods support regulatory compliance for maximum ZEN levels in foodstuffs.