Related Experiment Video
Updated: May 22, 2026

Cortical Bone Assessment Using Ultrasonic Guided Waves: A Reproducibility Study in a Healthy Population
Published on: January 31, 2025
Correlations between ultrasonic guided wave velocities and bone properties in bovine tibia in vitro
1Department of Physics, Kangwon National University, Chuncheon 200-701, Republic of Korea. acustica@kangwon.ac.kr
Abstract:
Correlations between ultrasonic guided wave velocities and bone properties were investigated in bovine tibia in vitro. The velocities of the first arriving signal and the slow guided wave, termed V(FAS) and V(SGW), along the long axis of the tibia were measured at 200 kHz in 20 bovine tibiae using the axial transmission technique. V(FAS) yielded significant negative correlation coefficients of -0.54 to -0.66 with the bone properties. In contrast, V(SGW) yielded strong positive correlation coefficients of 0.68-0.84. The best univariate predictor of V(FAS) and V(SGW) was the cortical thickness yielding adjusted squared correlation coefficients of 0.41 and 0.69, respectively.
Related Concept Videos
Bone Structure
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Imaging Studies II: Ultrasonography