Related Experiment Video
Updated: Aug 7, 2026

Investigation into Deep Breathing through Measurement of Ventilatory Parameters and Observation of Breathing Patterns
Published on: September 16, 2019
[Evaluation of a semi-closed underwater breathing apparatus, the "eOBA"]
1School of Kinesiology, Simon Fraser Univ., Burnaby, British Columbia, Canada.
Abstract:
Semi-closed underwater breathing apparatus has commonly been used among military and commercial divers, but never available for recreational divers because of complicated operations, difficulties of maintenance, and expensiveness. Nippon Sanso K.K. has newly deployed a semi-closed circuit underwater breathing apparatus called the "eOBA". It is especially designed for divers to enjoy shallow (max. 5 m) and short (10 min.) dives. This eOBA was evaluated from manned testing based on physiological requirements for the apparatus. Four male and four female subjects participated in the three test trials. Subjects maintained their position at the depths of 2 m and 4 m for 10 min. and e exercised on the underwater ergometer at the depth of 2.4 m. The pressure at the mouthpiece, tidal volume, breathing rate, the inspired O2 level, CO2 level were monitored on breath-by-breath basis. The inspired O2 level ranged from 45% (at exercise) to 60% (at rest) and the inspired CO2 level were kept less than 1.0% in the most cases. The P-V loop indicated relatively little external work of breathing (less than 0.1 kg.m/l) and allowable peak pressures (less than 25cmH2O). Results show that the eOBA meets the standards sufficiently under the test conditions and is a safe apparatus for recreational divers if it is properly used.
Related Concept Videos
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like asthma or COPD,...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration can...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Cardiopulmonary Resuscitation II: ACLS Airway Management

