Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Building a Clinically Relevant and Technically Robust Synthetic Histopathology Dataset for Breast and Gastric Cancer.

Journal of medical systems·2026
Same author

Radiomics-Based Machine Learning for Sarcopenia Detection in Abdominal and Low-Dose CT.

Diagnostics (Basel, Switzerland)·2026
Same author

Biomechanical stability evaluation of isolated straddle fracture using finite element analysis.

Scientific reports·2026
Same author

Deep learning-based automatic scoring of drug-induced sleep endoscopy in obstructive sleep apnea.

NPJ digital medicine·2026
Same author

Deep Learning-Based Prediction System for Surgical Difficulty in Rectal Cancer Patients Using MRI Pelvimetry.

Yonsei medical journal·2026
Same author

A Novel Fluorescence-Triggered Auditory Feedback Photosensor for Precision Lymph Node Mapping.

Sensors (Basel, Switzerland)·2026

Related Experiment Video

Updated: May 22, 2026

Human Brown Adipose Tissue Depots Automatically Segmented by Positron Emission Tomography/Computed Tomography and Registered Magnetic Resonance Images
09:21

Human Brown Adipose Tissue Depots Automatically Segmented by Positron Emission Tomography/Computed Tomography and Registered Magnetic Resonance Images

Published on: February 18, 2015

Body fat assessment method using CT images with separation mask algorithm.

Young Jae Kim1, Seung Hyun Lee, Tae Yun Kim

  • 1Biomedical Engineering Branch, Division of Convergence Technology, National Cancer Center, 323 Ilsan-ro, Ilsandong-gu, Goyang-si, Gyeonggi-do, 410-769, South Korea.

Journal of Digital Imaging
|May 11, 2012
PubMed
Summary
This summary is machine-generated.

Automated body fat assessment using computed tomography (CT) volume data shows high correlation with dual-energy X-ray absorptiometry (DEXA). This image processing technique offers a reliable method for quantitative body fat evaluation in clinical settings.

More Related Videos

Whole Body and Regional Quantification of Active Human Brown Adipose Tissue Using 18F-FDG PET/CT
10:30

Whole Body and Regional Quantification of Active Human Brown Adipose Tissue Using 18F-FDG PET/CT

Published on: April 1, 2019

Segmentation and Linear Measurement for Body Composition Analysis using Slice-O-Matic and Horos
13:35

Segmentation and Linear Measurement for Body Composition Analysis using Slice-O-Matic and Horos

Published on: March 21, 2021

Related Experiment Videos

Last Updated: May 22, 2026

Human Brown Adipose Tissue Depots Automatically Segmented by Positron Emission Tomography/Computed Tomography and Registered Magnetic Resonance Images
09:21

Human Brown Adipose Tissue Depots Automatically Segmented by Positron Emission Tomography/Computed Tomography and Registered Magnetic Resonance Images

Published on: February 18, 2015

Whole Body and Regional Quantification of Active Human Brown Adipose Tissue Using 18F-FDG PET/CT
10:30

Whole Body and Regional Quantification of Active Human Brown Adipose Tissue Using 18F-FDG PET/CT

Published on: April 1, 2019

Segmentation and Linear Measurement for Body Composition Analysis using Slice-O-Matic and Horos
13:35

Segmentation and Linear Measurement for Body Composition Analysis using Slice-O-Matic and Horos

Published on: March 21, 2021

Area of Science:

  • Medical Imaging
  • Biomedical Engineering
  • Radiology

Background:

  • Rising obesity rates in Korea necessitate accurate body fat measurement for health.
  • Quantitative body fat assessment is crucial for obesity prevention and diagnosis.
  • Dual-energy X-ray absorptiometry (DEXA) is a reliable but potentially time-consuming method.

Purpose of the Study:

  • To develop and validate an automated fat assessment procedure using computed tomography (CT) data.
  • To compare the accuracy of automated fat assessment from single CT images versus CT volume data against DEXA.
  • To establish the reliability of CT-based automated fat assessment for clinical application.

Main Methods:

  • Image processing techniques were applied to analyze CT data for fat quantification.
  • The automated method was tested on both single CT images and comprehensive CT volume data.
  • Results were correlated with measurements obtained from dual-energy X-ray absorptiometry (DEXA).

Main Results:

  • No significant correlation was found between DEXA and automated/manual assessments using single CT images (P > 0.05).
  • Highly significant correlations were observed between DEXA and automated assessments using CT volume data (r = 0.826, P < 0.01).
  • The proposed automated method using CT volume data demonstrated strong agreement with DEXA.

Conclusions:

  • Automated body fat assessment using CT volume data is a reliable and accurate method.
  • This technique shows potential for reducing the time required for quantitative body fat evaluation.
  • Clinical implementation of this automated CT-based method could aid in obesity management.