Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Potentiometry: Membrane Electrodes01:15

Potentiometry: Membrane Electrodes

Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at the...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Voltammetric Translation with Transformers: Converting Cyclic Voltammograms to Differential Pulse Voltammograms.

ACS measurement science au·2026
Same author

33 Unresolved Questions in Nanoscience and Nanotechnology.

ACS nano·2025
Same author

Three-state molecular switch based on terarylene photo- or redox-induced reversible isomerisation.

Chemical science·2025
Same author

Scalable electrochemical system for rapid on-site detection of food allergens.

Biosensors & bioelectronics·2025
Same author

Dual-Shaped Silver Nanoparticle Labels for Electrochemical Detection of Bioassays.

ACS applied nano materials·2024
Same author

Time-Resolved Electrochemical Impedance Spectroscopy of Stochastic Nanoparticle Collision: Short Time Fourier Transform versus Continuous Wavelet Transform.

Small (Weinheim an der Bergstrasse, Germany)·2023
Same journal

A two-step centrifugal microfluidic platform for semi-automated IGRA detection of tuberculosis based on chemiluminescence.

The Analyst·2026
Same journal

On-site rapid identification of animal and plant creams <i>via</i> 2D FeB nanozyme-based colorimetric sensors.

The Analyst·2026
Same journal

Sensitive detection of aflatoxin B1 using a dual-mode fluorescent aptasensor based on cascade signal amplification.

The Analyst·2026
Same journal

Deep learning-enabled microfluidic digital PCR platform for efficient seven-color quantification.

The Analyst·2026
Same journal

Monitoring food spoilage biogenic amines utilizing a blue-emitting fluorescent ionic liquid.

The Analyst·2026
Same journal

Correction: Regeneration-on-a-chip: a planarian microfluidic device enabling automated cultivation, individual tracking and <i>in vivo</i> imaging for regeneration study.

The Analyst·2026
See all related articles

Related Experiment Video

Updated: May 22, 2026

Multi-analyte Biochip (MAB) Based on All-solid-state Ion-selective Electrodes (ASSISE) for Physiological Research
08:03

Multi-analyte Biochip (MAB) Based on All-solid-state Ion-selective Electrodes (ASSISE) for Physiological Research

Published on: April 18, 2013

Two-channel microelectrochemical bipolar electrode sensor array.

Byoung-Yong Chang1, Kwok-Fan Chow, John A Crooks

  • 1Department of Chemistry, Pukyong National University, 45 Yongso-ro, Busan 608-739, Korea.

The Analyst
|May 12, 2012
PubMed
Summary
This summary is machine-generated.

This study introduces a novel two-channel microelectrochemical sensor using bipolar electrodes (BPEs) for improved chemical detection. The design physically separates sensing and reporting channels, preventing interference and enhancing electrogenerated chemiluminescence (ECL) signal accuracy.

More Related Videos

In Vitro Multiparametric Cellular Analysis by Micro Organic Charge-modulated Field-effect Transistor Arrays
10:05

In Vitro Multiparametric Cellular Analysis by Micro Organic Charge-modulated Field-effect Transistor Arrays

Published on: September 20, 2021

Double-barreled and Concentric Microelectrodes for Measurement of Extracellular Ion Signals in Brain Tissue
11:08

Double-barreled and Concentric Microelectrodes for Measurement of Extracellular Ion Signals in Brain Tissue

Published on: September 5, 2015

Related Experiment Videos

Last Updated: May 22, 2026

Multi-analyte Biochip (MAB) Based on All-solid-state Ion-selective Electrodes (ASSISE) for Physiological Research
08:03

Multi-analyte Biochip (MAB) Based on All-solid-state Ion-selective Electrodes (ASSISE) for Physiological Research

Published on: April 18, 2013

In Vitro Multiparametric Cellular Analysis by Micro Organic Charge-modulated Field-effect Transistor Arrays
10:05

In Vitro Multiparametric Cellular Analysis by Micro Organic Charge-modulated Field-effect Transistor Arrays

Published on: September 20, 2021

Double-barreled and Concentric Microelectrodes for Measurement of Extracellular Ion Signals in Brain Tissue
11:08

Double-barreled and Concentric Microelectrodes for Measurement of Extracellular Ion Signals in Brain Tissue

Published on: September 5, 2015

Area of Science:

  • Electrochemistry
  • Analytical Chemistry
  • Sensor Technology

Background:

  • Microelectrochemical sensors offer miniaturized analytical capabilities.
  • Bipolar electrode (BPE) technology enables communication between separate electrochemical compartments.
  • Existing BPE sensors can suffer from chemical interference between sensing and reporting elements.

Purpose of the Study:

  • To develop and characterize a two-channel microelectrochemical sensor.
  • To utilize bipolar electrodes (BPEs) for communication between distinct microchannels.
  • To physically separate sensing and reporting components to prevent cross-channel chemical interference.

Main Methods:

  • Fabrication of a two-channel microfluidic device.
  • Integration of one or more bipolar electrodes (BPEs) to link the channels.
  • Application of voltage across BPEs to activate simultaneous faradaic reactions.
  • Utilizing electrogenerated chemiluminescence (ECL) as the reporting mechanism.

Main Results:

  • Demonstrated communication between separate sensing and reporting microchannels via BPEs.
  • Achieved activation of faradaic reactions in both channels based on microchannel contents and applied voltage.
  • Successfully separated the ECL reporting cocktail from the target-containing solution.
  • Prevented chemical interference between the sensing and reporting channels.

Conclusions:

  • The developed two-channel microelectrochemical sensor effectively uses BPEs for signal transduction.
  • Physical separation of channels in the BPE sensor design mitigates chemical interference.
  • This architecture enhances the reliability and accuracy of ECL-based sensing applications.