Objective:
To illustrate a case of an iatrogenic mucosal tear in the trachea which caused a one-way valve effect, obstructing the airway and manifesting as post-extubation stridor.
Case Report:
We report a case of iatrogenic tracheal mucosal tear secondary to violent movement during intubation. The patient presented with post-extubation stridor that worsened over three days. Initial evidence suggested tracheal stenosis. Computed tomography scans revealed a mucosal tear at the level of the seventh cervical to second thoracic vertebrae. The tear was caused by forceful inflow of air as breathing became more and more difficult, resulting in a false tract. A tracheostomy changed the direction of airflow, bypassing the tear. The inflated tracheostomy tube cuff acted as a stent to keep the flap in place as healing occurred.
Conclusion:
Iatrogenic laryngotracheal injuries are common, especially when endotracheal intubation is performed under unfavourable emergency conditions. A tracheal mucosal tear is a rare entity which is almost always undiagnosed. However, a tracheal mucosal flap may be suspected when changes in patient position alter the nature and severity of the resultant stridor and/or respiratory distress. In such cases, an inflated tracheostomy tube cuff should be kept in place for an adequate period, to act as a stent and help keep the flap in place while healing occurs.
Related Concept Videos
Trachea
Anatomical Features:
Location: About half of the trachea is situated in the neck, anterior to the esophagus, and extends from the larynx (at the level of the...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Tracheostomy Care I: Pre-procedural Steps
Required Equipment
The equipment necessary for tracheostomy care includes:
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Flail Chest-II
Assessment:
1. Clinical Evaluation:
History: