Related Experiment Video
Updated: May 22, 2026

High-Temperature and High-Pressure In situ Magic Angle Spinning Nuclear Magnetic Resonance Spectroscopy
Published on: October 9, 2020
Utilizing afterglow magnetization from cross-polarization magic-angle-spinning solid-state NMR spectroscopy to obtain
James R Banigan1, Nathaniel J Traaseth
1Department of Chemistry, New York University, New York, New York 10003, USA.
Abstract:
The time required for data acquisition and subsequent spectral assignment are limiting factors for determining biomolecular structure and dynamics using solid-state NMR spectroscopy. While strong magnetic dipolar couplings give rise to relatively broad spectra lines, the couplings also mediate the coherent magnetization transfer via the Hartmann-Hahn cross-polarization (HH-CP) experiment. This mechanism is used in nearly all backbone assignment experiments for carrying out polarization transfer between (1)H, (15)N, and (13)C. In this Article, we describe a general spectroscopic approach to use the residual or "afterglow" magnetization from the (15)N to (13)C selective HH-CP experiment to collect a second multidimensional heteronuclear data set. This approach allowed for the collection of two commonly used sequential assignment experiments (2D NCA and NCO or 3D NCACX and NCOCX) at the same time. Our "afterglow" technique was demonstrated with uniformly [(13)C,(15)N] and [1,3-(13)C] glycerol-labeled ubiquitin using instrumentation available on all standard solid-state NMR spectrometers configured for magic-angle-spinning. This method is compatible with several other sensitivity enhancement experiments and can be used as an isotopic filtering tool to reduce the spectral complexity and decrease the time needed for assignment.
More Related Videos
10:28Measuring Interactions of Globular and Filamentous Proteins by Nuclear Magnetic Resonance Spectroscopy (NMR) and Microscale Thermophoresis (MST)
Published on: November 2, 2018
14:55Atomic Scale Structural Studies of Macromolecular Assemblies by Solid-state Nuclear Magnetic Resonance Spectroscopy
Published on: September 17, 2017
Related Concept Videos
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...
2D NMR: Overview of Heteronuclear Correlation Techniques
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
2D NMR: Overview of Homonuclear Correlation Techniques
COSY90 is the standard two-dimensional (2D) COSY experiment that...
NMR Spectroscopy: Spin–Spin Coupling
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...