Related Experiment Video
Updated: May 22, 2026

Inactivation of Pathogens via Visible-Light Photolysis of Riboflavin-5′-Phosphate
Published on: April 6, 2022
High-intensity 405 nm light inactivation of Listeria monocytogenes
Endarko Endarko1, Michelle Maclean, Igor V Timoshkin
1The Robertson Trust Laboratory for Electronic Sterilisation Technologies, Department of Electronic and Electrical Engineering, University of Strathclyde, Glasgow, UK.
Abstract:
The antimicrobial properties of light is an area of increasing interest. This study investigates the sensitivity of the significant foodborne pathogen Listeria monocytogenes to selected wavelengths of visible light. Results demonstrate that exposure to wavelength region 400-450 nm, at sufficiently high dose levels (750 J cm(-2)), induced complete inactivation of a 5 log(10) population. Exposure to wavelengths longer than 450 nm did not cause significant inactivation. Analysis of 10 nm bandwidths between 400 and 450 nm confirmed 405(± 5) nm light to be most effective for the inactivation of L. monocytogenes, with a lesser bactericidal effect also evident at other wavelengths between 400 and 440 nm. Identification of the optimum bactericidal wavelength enabled the comparison of inactivation using 405(± 5) nm filtered light and a 405 nm light-emitting diode (LED) array (14 nm FWHM). Results demonstrate similar inactivation kinetics, indicating that the applied dose of 405 nm light is the important factor. Use of the 405 nm LED array for the inactivation of L. monocytogenes and other Listeria species resulted in similar kinetics, with up to 5 log(10) reductions with a dose of 185 J cm(-2). Comparative data for the 405 nm light inactivation of L. monocytogenes and other important foodborne pathogens, Escherichia coli, Salmonella enteritidis and Shigella sonnei, are also presented, with L. monocytogenes showing higher susceptibility to inactivation through 405 nm light exposure.
More Related Videos
09:29In Vivo Investigation of Antimicrobial Blue Light Therapy for Multidrug-resistant Acinetobacter baumannii Burn Infections Using Bioluminescence Imaging
Published on: April 28, 2017
05:13LED-Based In Vitro Screening for Assessing Photoactivable Molecules in Bacterial Photodynamic Inactivation
Published on: January 24, 2025
Related Concept Videos
Physical Methods for Controlling Microbial Growth: Temperature
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...