Related Experiment Video
Updated: May 22, 2026

Fabrication of Compressed Hosiery and Measurement of its Pressure Characteristic Exerted on the Lower Limbs
Published on: May 27, 2020
Comparison of the interface pressure and stiffness of four types of compression systems
I K Y Wong1, M B L Man, O S H Chan
1School of Nursing, Hong Kong Sanatorium and Hospital, Hong Kong, HKSAR.
Objective:
To compare interface pressure (IP) and static stiffness index (SSI) of four different compression systems currently in use for the treatment of patients with venous leg ulcer.
Method:
Fifty-two ambulatory adults with healthy legs were recruited at random at a study centre after they had consented. The evaluated systems were: short-stretch system (SSB), Rosidal sys (Lohmann & Rauscher), multilayer bandaging (LSB) Profore (Smith & Nephew), Vari-stretch (VSB) ProGuide (Smith & Nephew) and tubular compression (CS) Rosidal Mobil (Lohmann & Rauscher). Interface pressure was measured using Kikuhime (Harada Corp.), placing a 3 cm-diameter probe at the B1 point. IP recording took place in the supine and standing positions, while sitting and during walking, on application of the compression systems and every 15 minutes thereafter for 4 hours.
Results:
The IPs of SSB, LSB and VSB, measured immediately after bandage application, were significantly higher than that of CS (all p < 0.05). During the 4-hour study period, the IP for both VSB and LSB measured in the supine position initially increased to > 60 mmHg. Their overall mean IPs in the supine position were 48.96 ± 3.99 mmHg and 48.12 ± 4.57 mmHg, respectively. SSB and CS demonstrated more tolerable IP levels in this position of < 40 mmHg, which was similar to those when sitting. All systems maintained at least 40 mmHg in walking. SSB had a high SSI of 20 throughout the study. LSB followed with an SSI of 18 at the start, which reduced to 13, while the SSI for VSB decreased from 17 to 12 and CS, with an SSI of 6, lagged behind.
Conclusion:
These results may contribute to the understanding of IP and SSI of the four different compression systems evaluated. The IP and SSI data presented give clinicians an indication of the appropriate frequency of re-application of compression, and preliminary data on choosing a safe and effective compression treatment for their patients.
Declaration Of Interest:
The investigators received an educational grant from Lohmann & Rauscher GmbH & Co KG for this study.
Related Concept Videos
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
Application of Pascal's Law
Hydraulic systems are used to operate automotive brakes, hydraulic jacks, and numerous other mechanical systems. We can derive a relationship between the forces in a simple hydraulic system by applying...
Stress: General Loading Conditions
The shearing force, possessing potential directionality within the plane of the section, is simplified into two component forces running parallel to the x and y axes.
Applications of Stress
The...
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs during...
Pressure Variation in a Fluid at Rest
When measuring pressure at two different levels within the fluid, the difference in pressure...