Effectiveness and safety of the Levitan FPS Scope™ for tracheal intubation under general anesthesia with a simulated difficult airway
Related Experiment Video
Updated: May 22, 2026

The Flexible Rhino-Laryngoscope for Awake Nasotracheal Intubation
Published on: August 2, 2024
Tracy Kok1, Ronald B George, Dolores McKeen
1Department of Women's & Obstetric Anesthesia, IWK Health Centre, Dalhousie University, 5850/5980 University Avenue, P.O. Box 9700, Halifax, NS, B3K 6R8, Canada.
Purpose:
Studies show that the Levitan FPS (first pass success) Scope™ (LFS) is analogous to a bougie in simulated difficult airways with comparable tracheal intubation success rates. In this study, the efficacy and safety of tracheal intubation with the LFS was compared with that of the Macintosh laryngoscope utilizing manual in-line stabilization (MILS) to simulate difficult airways.
Methods:
Ninety-four subjects successfully completed the trial. Manual in-line stabilization of the cervical spine was applied and the initial laryngoscopy was performed using either the Macintosh or the LFS in conjunction with the Macintosh. Following the initial grading, a second laryngoscopy was repeated using the second randomized technique. Cormack-Lehane grades, percentage of glottic opening (POGO) scores, time to intubate, number of intubation attempts, and the use of alternate techniques were recorded. The anesthesiologist rated the subjective difficulty in using each technique with a numeric rating scale and a visual rating scale.
Results:
There was no significant difference in the primary outcome "good laryngoscopic views" (Cormack-Lehane grade 1 and 2) compared with "poor laryngoscopic views" (Cormack-Lehane grade 3 and 4) between the LFS and the Macintosh. There were higher POGO scores with the LFS compared with the Macintosh (80% vs 20%, respectively; P < 0.0001), but this did not translate to easier intubations, as documented by the need for an alternate intubation technique or time to intubate (< 30 and < 60 sec, respectively). The incidence of mucosal trauma, sore throat, and hemodynamic responses did not differ significantly between the two techniques.
Conclusion:
The LFS in conjunction with the Macintosh laryngoscope does not improve the efficacy or safety of tracheal intubation in a simulated difficult airway.
Related Concept Videos
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals.
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...