Related Experiment Video
Updated: May 22, 2026

A Microfluidic Flow Chamber Model for Platelet Transfusion and Hemostasis Measures Platelet Deposition and Fibrin Formation in Real-time
Published on: February 14, 2017
Effect of carryover of clot activators on coagulation tests during phlebotomy
Yoko Fukugawa1, Hiroaki Ohnishi, Takahiro Ishii
1Department of Laboratory Medicine, Kyorin University School of Medicine, Mitaka, Tokyo, Japan.
We investigated the effect of clot activators carried over from the serum tube on major coagulation tests during phlebotomy. First, blood specimens from 30 normal subjects were mixed with small amounts of fluid containing clot activators, and their effects on various coagulation tests were determined. Only the value of fibrin monomer complex displayed a remarkable change when thrombin-containing fluid was added to the blood specimens. Subsequently, 100 paired blood specimens (taken from 75 healthy volunteers and 25 patients taking warfarin) were collected in coagulation tubes before and after the serum tube using standard phlebotomy procedures. Various coagulation tests were performed to determine the effect of contamination of thrombin-containing blood on coagulation parameters. Differences between the 2 tubes were minimal but significant for some of the coagulation tests. Therefore, we conclude that the effect of clot activators in the serum tube on coagulation tests is minimal when standard phlebotomy procedures are used.
We investigated the effect of clot activators carried over from the serum tube on major coagulation tests during phlebotomy. First, blood specimens from 30 normal subjects were mixed with small amounts of fluid containing clot activators, and their effects on various coagulation tests were determined. Only the value of fibrin monomer complex displayed a remarkable change when thrombin-containing fluid was added to the blood specimens. Subsequently, 100 paired blood specimens (taken from 75 healthy volunteers and 25 patients taking warfarin) were collected in coagulation tubes before and after the serum tube using standard phlebotomy procedures. Various coagulation tests were performed to determine the effect of contamination of thrombin-containing blood on coagulation parameters. Differences between the 2 tubes were minimal but significant for some of the coagulation tests. Therefore, we conclude that the effect of clot activators in the serum tube on coagulation tests is minimal when standard phlebotomy procedures are used.
Related Concept Videos
Disorders of Hemostasis
Thromboembolic Disorders
Two factors primarily cause thromboembolic conditions.
Coagulation
During the coagulation phase, clotting factors, or procoagulants, play a vital role in initiating and progressing the coagulation cascade. This cascade is a series of reactions...
Extrinsic and Intrinsic Pathways of Hemostasis
The Extrinsic Pathway
The extrinsic pathway of coagulation is typically initiated by tissue damage that exposes blood to tissue factor (TF), a protein released by the damaged tissue cells outside the blood vessels—this interaction with TF triggers biochemical reactions involving specific clotting factors. The key player here is Factor VII, which forms a...
Anticoagulant Drugs: Low-Molecular-Weight Heparins
Venous Thrombosis III: Interprofessional Care
Clot Retraction and Fibrinolysis

