Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Focusing of Light in the Eye01:16

Focusing of Light in the Eye

Light rays enter the eye through the cornea, a transparent dome-shaped tissue that is the eye's outermost layer. The cornea bends or refracts, light rays traveling to the pupil. The shape of the cornea determines how much of the light is bent and whether the image will be focused correctly on the retina at the back of the eye. Once the light has passed through both refraction layers, it converges into a single focal point onto a small area. This is where photoreceptors start transforming...
Confocal Fluorescence Microscopy01:16

Confocal Fluorescence Microscopy

Confocal microscopy is an advanced microscopic technique. The prime advantage of the confocal microscope over other microscopy techniques is its ability to block the out-of-focus light from the illuminated samples using pinholes. It is widely used with fluorescence optics to obtain high-resolution, sharp contrast images. Unlike optical microscopes, confocal microscopes use a focused beam of light laser to scan the entire sample surface at different z-planes. These microscopes are, therefore,...
Phase Contrast and Differential Interference Contrast Microscopy01:26

Phase Contrast and Differential Interference Contrast Microscopy

Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

The answer is 23 years - what is the question? Understanding the time lag between ophthalmic research and clinical adoption.

Contact lens & anterior eye : the journal of the British Contact Lens Association·2026
Same author

Effect of a head strap on the function of an eyelid warming compress.

Contact lens & anterior eye : the journal of the British Contact Lens Association·2026
Same author

Diagnostic utility of inflammation-associated clinical signs in detecting MMP-9 expression in dry eye disease: A cross-sectional conjunctival impression cytology and droplet digital PCR study.

Contact lens & anterior eye : the journal of the British Contact Lens Association·2026
Same author

Optimising slit-lamp biomicroscope fluorescein imaging filters.

Contact lens & anterior eye : the journal of the British Contact Lens Association·2026
Same author

Reimagining dry eye disease management - a multimodal approach targeting the key pathophysiological drivers.

Contact lens & anterior eye : the journal of the British Contact Lens Association·2026
Same author

Corrigendum to "TFOS DEWS III: Digest" Am J Ophthalmol. 2025; 279:451-553.

American journal of ophthalmology·2026
Same journal

Loss of ATRAID in Late-Onset, Non-Syndromic Retinitis Pigmentosa.

Investigative ophthalmology & visual science·2026
Same journal

Whole-Exome Analysis Identifies Candidate Genes Associated With Diabetic Retinopathy.

Investigative ophthalmology & visual science·2026
Same journal

Antiseptic Efficacy and Ocular Surface Toxicity of Povidone-Iodine and Chlorhexidine for Endophthalmitis Isolates.

Investigative ophthalmology & visual science·2026
Same journal

Ocular IL-1α/IFN-γ Delay the Corneal Wound Healing in Rheumatoid Arthritis Through Mitochondrial Dysfunction and NLRP3 Inflammasome Activation.

Investigative ophthalmology & visual science·2026
Same journal

New Guidelines for Ophthalmic Genetic Studies.

Investigative ophthalmology & visual science·2026
Same journal

Genomic Copy Number Variants Associated With Strabismus and Amblyopia in the All of Us Research Program.

Investigative ophthalmology & visual science·2026
See all related articles

Related Experiment Video

Updated: May 22, 2026

Scanning Light Scattering Profiler (SLPS) Based Methodology to Quantitatively Evaluate Forward and Backward Light Scattering from Intraocular Lenses
06:55

Scanning Light Scattering Profiler (SLPS) Based Methodology to Quantitatively Evaluate Forward and Backward Light Scattering from Intraocular Lenses

Published on: June 6, 2017

Multifocal intraocular lens differentiation using defocus curves.

Phillip J Buckhurst1, James S Wolffsohn, Shehzad A Naroo

  • 1Ophthalmic Research Group, School of Life and Health Sciences, Aston University, Birmingham, United Kingdom. phillip.buckhurst@plymouth.ac.uk

Investigative Ophthalmology & Visual Science
|May 17, 2012
PubMed
Summary
This summary is machine-generated.

The area-of-focus metric effectively differentiates multifocal intraocular lens (MIOL) designs, unlike traditional depth-of-focus methods. This new approach correlates well with subjective visual perception, offering a simpler evaluation of MIOL performance.

More Related Videos

Multifocal Electroretinograms
16:49

Multifocal Electroretinograms

Published on: December 4, 2011

Spatio-Temporal In Vivo Imaging of Ocular Drug Delivery Systems using Fiberoptic Confocal Laser Microendoscopy
07:12

Spatio-Temporal In Vivo Imaging of Ocular Drug Delivery Systems using Fiberoptic Confocal Laser Microendoscopy

Published on: September 27, 2021

Related Experiment Videos

Last Updated: May 22, 2026

Scanning Light Scattering Profiler (SLPS) Based Methodology to Quantitatively Evaluate Forward and Backward Light Scattering from Intraocular Lenses
06:55

Scanning Light Scattering Profiler (SLPS) Based Methodology to Quantitatively Evaluate Forward and Backward Light Scattering from Intraocular Lenses

Published on: June 6, 2017

Multifocal Electroretinograms
16:49

Multifocal Electroretinograms

Published on: December 4, 2011

Spatio-Temporal In Vivo Imaging of Ocular Drug Delivery Systems using Fiberoptic Confocal Laser Microendoscopy
07:12

Spatio-Temporal In Vivo Imaging of Ocular Drug Delivery Systems using Fiberoptic Confocal Laser Microendoscopy

Published on: September 27, 2021

Area of Science:

  • Ophthalmology
  • Optics
  • Biomedical Engineering

Background:

  • Multifocal intraocular lenses (MIOLs) are designed to provide vision at multiple distances.
  • Assessing the visual performance of different MIOL designs is crucial for clinical application.
  • Defocus curve assessment is a common method to evaluate visual function after lens implantation.

Purpose of the Study:

  • To identify the most suitable analysis technique for distinguishing between various multifocal intraocular lens (MIOL) designs.
  • To evaluate the efficacy of defocus curve assessment in differentiating MIOL visual capabilities.

Main Methods:

  • Four groups of 15 subjects received either monofocal, refractive MIOL, diffractive MIOL, or a combination of MIOLs.
  • Defocus curves were analyzed using depth-of-focus, direct comparison, and a novel area-of-focus metric.
  • Results were correlated with subjective assessments of near and intermediate vision.

Main Results:

  • Depth-of-focus methods were insufficient for differentiating MIOL groups.
  • The area-of-focus metric showed significant differences between MIOL designs for intermediate and near vision zones.
  • Subjective visual perception correlated best with the area-of-focus metric.

Conclusions:

  • Conventional depth-of-focus metrics lack the detail to differentiate MIOL designs effectively.
  • The direct comparison method offers extensive data but can be complex to interpret.
  • The proposed area-of-focus metric provides a simple yet effective method for evaluating MIOL defocus curves.