Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Radiological Investigation III: Pulmonary Angiogram and PET Scan01:13

Radiological Investigation III: Pulmonary Angiogram and PET Scan

Radiological investigations are paramount in the diagnosis and management of various pulmonary diseases. Two essential investigations are the Pulmonary Angiogram and the Positron Emission Tomography (PET) Scan.
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System III: X-Ray01:20

Imaging Studies for Cardiovascular System III: X-Ray

The most common cardiovascular diagnostic test is an X-ray. It produces images of the heart, blood vessels, and adjacent structures.
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Radiological Investigation I: X-ray and CT01:30

Radiological Investigation I: X-ray and CT

Radiological investigations, including X-rays and computed tomography (CT) scans, are critical for diagnosing and evaluating various medical conditions. These imaging techniques provide valuable insights into the body's internal structures, aiding in the detection of abnormalities, assessment of disease progression, and development of treatment strategies. This article delves into two primary radiological investigations, chest X-rays and CT scans, outlining their purpose, procedures, and the...
Imaging Studies for Cardiovascular System V: CT01:28

Imaging Studies for Cardiovascular System V: CT

Cardiac computed tomography (CT) scanning is an advanced cardiac imaging technique that utilizes CT technology, with or without intravenous (IV) contrast, to produce accurate cross-sectional virtual slices of specific areas of the heart, coronary circulation, and major blood vessels such as the aorta, pulmonary veins, and arteries. The computer processes these slices to generate three-dimensional images. Multidetector CT (MDCT) is a rapid form of CT scanning that captures multiple slices...
X-ray Imaging01:24

X-ray Imaging

German physicist Wilhelm Röntgen (1845–1923) was experimenting with electrical current when he discovered that a mysterious and invisible "ray" would pass through his flesh but leave an outline of his bones on a screen coated with a metal compound. In 1895, Röntgen made the first durable record of the internal parts of a living human: an "X-ray" image (as it came to be called) of his wife’s hand. Scientists worldwide quickly began their own experiments with X-rays, and by 1900, X-ray was widely...
Biological Effects of Radiation02:59

Biological Effects of Radiation

All radioactive nuclides emit high-energy particles or electromagnetic waves. When this radiation encounters living cells, it can cause heating, break chemical bonds, or ionize molecules. The most serious biological damage results when these radioactive emissions fragment or ionize molecules. For example, α and β particles emitted from nuclear decay reactions possess much higher energies than ordinary chemical bond energies. When these particles strike and penetrate matter, they produce ions...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Establishment of local diagnostic reference levels in paediatric screen-film radiography at a children's hospital.

Radiation protection dosimetry·2012
Same author

A survey of computed tomography imaging techniques and patient dose in Kenya.

East African medical journal·2012
Same author

Optimisation of patient protection and image quality in diagnostic radiology.

East African medical journal·2012
Same author

Patient doses using multidetector computed tomography scanners in Kenya.

Radiation protection dosimetry·2012
Same author

Paediatric CT examinations in 19 developing countries: frequency and radiation dose.

Radiation protection dosimetry·2010
Same author

Patient doses in CT examinations in 18 countries: initial results from International Atomic Energy Agency projects.

Radiation protection dosimetry·2009

Related Experiment Video

Updated: May 22, 2026

Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
13:48

Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound

Published on: April 21, 2023

Radiation exposure in interventional procedures.

G K Korir1, B O Ochieng, J S Wambani

  • 1Department of Physics and Applied Physics, University of Massachusetts Lowell, One University Ave., Lowell, MA 01854, USA. chumo2009@gmail.com

Radiation Protection Dosimetry
|May 22, 2012
PubMed
Summary

This study assessed radiation doses for patients and staff during interventional procedures in Kenya. Findings indicate a need for dose containment strategies to prevent exceeding radiation safety limits, especially for eye lens exposure.

More Related Videos

Magnetically-Assisted Remote Controlled Microcatheter Tip Deflection under Magnetic Resonance Imaging
11:27

Magnetically-Assisted Remote Controlled Microcatheter Tip Deflection under Magnetic Resonance Imaging

Published on: April 4, 2013

Non-fluoroscopic Catheter Tracking for Fluoroscopy Reduction in Interventional Electrophysiology
10:46

Non-fluoroscopic Catheter Tracking for Fluoroscopy Reduction in Interventional Electrophysiology

Published on: May 26, 2015

Related Experiment Videos

Last Updated: May 22, 2026

Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
13:48

Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound

Published on: April 21, 2023

Magnetically-Assisted Remote Controlled Microcatheter Tip Deflection under Magnetic Resonance Imaging
11:27

Magnetically-Assisted Remote Controlled Microcatheter Tip Deflection under Magnetic Resonance Imaging

Published on: April 4, 2013

Non-fluoroscopic Catheter Tracking for Fluoroscopy Reduction in Interventional Electrophysiology
10:46

Non-fluoroscopic Catheter Tracking for Fluoroscopy Reduction in Interventional Electrophysiology

Published on: May 26, 2015

Area of Science:

  • Medical Physics
  • Radiology
  • Occupational Health

Background:

  • Interventional procedures (IPs) involve significant radiation exposure for patients and staff.
  • Establishing national diagnostic reference levels (NDRLs) is crucial for radiation safety in healthcare.
  • Limited data exists on radiation doses from IPs in Kenya.

Purpose of the Study:

  • To estimate patient and staff radiation doses during IPs in Kenya.
  • To compare these doses with international diagnostic reference levels (IDRLs).
  • To propose initial National Diagnostic Reference Levels (NDRLs) for Kenya.

Main Methods:

  • Retrospective data collection from four Kenyan hospitals performing IPs.
  • Real-time radiation dose measurements: kerma-area product (KAP) and fluoroscopy time for patients.
  • Peak skin dose (PSD) measurement using EDR2 radiographic films and staff occupational doses using thermoluminescence dosemeters.

Main Results:

  • Patient KAP ranged from 4.2 to 137.1 Gy cm², and PSD from 52 to 740 mGy.
  • Fluoroscopy times varied between 3.3 and 70 minutes.
  • Staff doses per procedure ranged from 0.03 to 1.41 mSv, with potential for exceeding eye lens dose limits due to increased workload.

Conclusions:

  • Patient doses were within skin injury thresholds, but staff eye lens doses may exceed limits with increased workload.
  • Urgent need for dose containment strategies, including protective equipment and optimized practices.