Related Experiment Video
Updated: May 22, 2026

High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
Gamma radiation measurements and Monte Carlo computations following myocardial perfusion imaging with 201Tl
1Department of Electrical and Computer Engineering, Aristotle University of Thessaloniki, Thessaloniki GR-54124, Greece. clouvas@eng.auth.gr
Abstract:
In the current study, the time-dependent retention of (201)Tl-thallous chloride (111 MBq) was measured in a 56-y-old man undergoing myocardial perfusion imaging. For 23 d following the (201)Tl injection, total-body retained activity was measured by (i) in situ gamma spectrometry using a portable high-purity germanium (HPGe) detector and (ii) ex vivo urine radioassay using a shielded HPGe detector. The time-dependent decrease in total-body activity followed a monoexponential function, exp(-0.011 t), with an excellent correlation (R(2)=0.9988) between the experimental data and the fitted values. The effective half-life, Teff, of (201)Tl (physical half-life, Tph: 72.9 h) was therefore 63 h and the biological half-life, Tb, 463 h=19.3 d, identical to those measured in the same patient in 1997 (i.e. 14 y ago). The time-dependent decrease in the urine activity concentration, which followed a monoexponential function, exp(-0.0115 t), corroborated the foregoing results. The correlation (R(2)=0.9939) between the experimental data and the fitted values was again excellent. The effective half-life, Teff, was 60.26 h and the biological half-life, Tb, 348 h=14.5 d. Monte Carlo simulation using a simple model of the patient as a unit-density cylinder filled with water and containing a uniform distribution of (201)Tl yielded photon flux results in reasonable agreement with the measured data.
More Related Videos
08:36Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
09:55Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...