Related Experiment Video
Updated: May 22, 2026

Arterial Pouch Microsurgical Bifurcation Aneurysm Model in the Rabbit
Published on: May 14, 2020
Anteroapical aneurysm plication improves mechanical intraventricular dyssynchrony in patients with anterior
Xin-sheng Huang1, Cheng-xiong Gu, Jun-feng Yang
1Department of Cardiac Surgery, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.
Background:
Left ventricular (LV) dyssynchrony has been described to occur in patients with myocardial infarction. Dyssynchrony of left ventricular mechanical contraction produces adverse hemodynamic consequences. This study aimed to test the capacity of geometric rebuilding by aneurysm plication to restore a more synchronous contractile pattern after a mechanical, rather than electrical, intervention.
Methods:
A total of sixty patients with anterior myocardial infarction, QRS duration < 120 ms, electively undergoing operation between January 2008 and January 2010 were included for analysis. Real-time 3-dimensional echocardiography was performed to assess LV function, LV systolic and diastolic dyssynchrony by measuring ejection fraction (EF), peak ejection rate (PER), peak filling rate (PFR) and LV dyssynchrony. LV dyssynchrony was defined as the systolic dyssynchrony of the time to reach the minimum systolic volume for 16 LV segments, expressed in percent cardiac cycle, systolic dyssynchrony index (SDI). We compared changes of LV dyssynchrony at different interval times.
Results:
LV contraction was significantly asynchronous because preoperative SDI was higher, EF, PER and PFR were lowered. Compared with function after operation, LV mechanical intraventricular resynchronization was improved with decreased SDI ((8.7 ± 0.5)% vs. (14.3 ± 1.6)%, P = 0.01); LV function was improved with EF increasing ((43 ± 9)% vs. (37 ± 7)%, P = 0.001), and LV systolic and diastolic dyssynchrony was improved with more rapid PFR (199.4 ± 15.6 vs. 148.4 ± 21.2, P = 0.002) and PER (212.4 ± 14.5 vs. 156.3 ± 26.2, P = 0.001).
Conclusions:
Systolic and diastolic dyssynchrony was highly prevalent in patients with aneurysm, irrespective of QRS duration. Aneurysm plication produces a mechanical intraventricular resynchronization.
More Related Videos
11:58Minimally Invasive Thumb-sized Pterional Craniotomy for Surgical Clip Ligation of Unruptured Anterior Circulation Aneurysms
Published on: August 11, 2015
05:41Left Anterior Descending Coronary Artery Ligation for Ischemia-Reperfusion Research: Model Improvement via Technical Modifications and Quality Control
Published on: December 16, 2022