Imaging Studies IV: Magnetic Resonance Imaging01:27

Imaging Studies IV: Magnetic Resonance Imaging

Introduction:Magnetic Resonance Imaging, or MRI, can include a specialized imaging technique of the urinary system known as Magnetic Resonance Urography (MRU). This radiation-free technique uses strong magnetic fields and radio waves to produce detailed images with the help of a computer. MRU is particularly effective for visualizing fluid-filled structures like the kidneys, ureters, and bladder.Applications of MRI in the Genitourinary SystemKidneys and Ureters: MRI detects tumors, cysts,...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

(Cost-)effectiveness of focal therapy versus radical therapy (standard of care) in the treatment of men with intermediate-risk prostate cancer: study protocol for the ENFORCE focal randomised controlled trial.

BMJ open·2026
Same author

Changes in liver resections and associated outcomes over thirty years: a nationwide analysis using a machine learning approach.

European journal of surgical oncology : the journal of the European Society of Surgical Oncology and the British Association of Surgical Oncology·2026
Same author

WHO 2022 Renal Cell Tumor Classification: Imaging Features and Clinical Implications.

Radiographics : a review publication of the Radiological Society of North America, Inc·2026
Same author

Diagnostic assessment of artificial intelligence reconstruction on accelerated prostate MRI: a retrospective, paired, multi-reader multi-case study.

European radiology·2026
Same author

Quantifying hepatic arterial blood flow with 4D flow MRI: an in vivo feasibility and repeatability study.

Magma (New York, N.Y.)·2026
Same author

Dose Heterogeneity in Transarterial Radioembolization after Fractional Administration of Holmium Microspheres: A Study in Perfused Human Tumor-Bearing Liver Explants under MR Imaging.

Journal of vascular and interventional radiology : JVIR·2026

Related Experiment Video

Updated: May 22, 2026

A Cognitive Fusion-guided Prostate Biopsy Using Multiparametric Magnetic Resonance Imaging and Transrectal Ultrasound
06:08

A Cognitive Fusion-guided Prostate Biopsy Using Multiparametric Magnetic Resonance Imaging and Transrectal Ultrasound

Published on: March 21, 2025

MRI-guided and robotic-assisted prostate biopsy.

Jurgen J Fütterer1, Jelle O Barentsz

  • 1Department of Radiology, Radboud University Nijmegen Medical Centre, Nijmegen, The Netherlands. j.futterer@rad.umcn.nl

Current Opinion in Urology
|May 24, 2012
PubMed
Summary

MRI-guided robotic prostate biopsy shows promise for cancer detection. However, current clinical evidence is limited, with most research on phantoms rather than patients, necessitating further investigation.

More Related Videos

Use of MRI-ultrasound Fusion to Achieve Targeted Prostate Biopsy
09:11

Use of MRI-ultrasound Fusion to Achieve Targeted Prostate Biopsy

Published on: April 9, 2019

Related Experiment Videos

Last Updated: May 22, 2026

A Cognitive Fusion-guided Prostate Biopsy Using Multiparametric Magnetic Resonance Imaging and Transrectal Ultrasound
06:08

A Cognitive Fusion-guided Prostate Biopsy Using Multiparametric Magnetic Resonance Imaging and Transrectal Ultrasound

Published on: March 21, 2025

Use of MRI-ultrasound Fusion to Achieve Targeted Prostate Biopsy
09:11

Use of MRI-ultrasound Fusion to Achieve Targeted Prostate Biopsy

Published on: April 9, 2019

Area of Science:

  • Medical imaging
  • Robotics
  • Urology

Background:

  • Transrectal ultrasound-guided biopsy is the current standard for prostate cancer detection.
  • Multiparametric MRI offers advanced imaging for cancer detection and localization.
  • Prostate cancer diagnosis and treatment require precise intervention techniques.

Purpose of the Study:

  • To review and discuss recent advancements in MRI-compatible robot-guided prostate interventions.
  • To evaluate the feasibility and clinical applicability of robotic systems in MRI-guided prostate procedures.
  • To critically assess the current state of MRI-guided robotic prostate biopsy.

Main Methods:

  • Review of recent developments in MRI-compatible robotic systems for prostate interventions.
  • Analysis of studies investigating the feasibility of these robotic devices in closed-bore MRI systems.
  • Evaluation of existing patient and phantom studies on MRI-guided robotic prostate biopsy.

Main Results:

  • Several MRI-compatible robots have been developed, from manual manipulators to automated systems.
  • Feasibility studies have been conducted, primarily in phantom models, with limited patient-based research.
  • A small number of patients have undergone MRI-guided, robotic-assisted prostate biopsy, showing promising but preliminary results.

Conclusions:

  • The combination of MRI-guidance and robotic assistance presents a promising approach for prostate cancer detection.
  • Current clinical evidence supporting this technique is limited due to a lack of extensive patient studies.
  • The clinical value of MRI-guided robotic prostate biopsy remains speculative and requires further research.