Related Experiment Video
Updated: May 22, 2026

Rapid Point-of-Care Assay of Enoxaparin Anticoagulant Efficacy in Whole Blood
Published on: October 12, 2012
Low-density solvent-based dispersive liquid-liquid microextraction followed by high performance liquid chromatography
Hoda Ghambari1, Mohammadreza Hadjmohammadi
1Department of Chemistry, University of Mazandaran, Babolsar 47416-95447, Iran.
Abstract:
Extraction and determination of warfarin, a widely used anticoagulant drug, in human plasma were performed using a new generation of dispersive liquid-liquid microextraction (DLLME) and high performance liquid chromatography (HPLC). The extraction procedure is based on extraction solvents lighter than water and performing of extraction in a specially designed extraction cell. Some important parameters, including kind and volume of extraction and disperser solvents, pH of the sample solution, salt concentration in the sample solution and extraction time were investigated and optimized. Under the optimized conditions (150 μL 1-octanol as extraction solvent, 150 μL methanol as disperser solvent, pH(sample)=2.3, extraction time of 2 min, without salt addition), limit of detection (LOD) of 5 ng mL⁻¹ and extraction recovery of 91.0% were obtained. The calibration curve was linear within the range of 15-3000 ng mL⁻¹ with the square of correlation coefficient (R²) of 0.998. Repeatability and reproducibility of method based on five replicate extraction and determination were 2.8% and 6.5%, respectively. The proposed method was applied successfully for the determination of warfarin in plasma sample from a patient under treatment with this drug, and was demonstrated to be sensitive, efficient, and convenient.
More Related Videos
14:39Semi-Targeted Ultra-High-Performance Chromatography Coupled to Mass Spectrometry Analysis of Phenolic Metabolites in Plasma of Elderly Adults
Published on: April 22, 2022
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019
Related Concept Videos
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Anticoagulant Drugs: Low-Molecular-Weight Heparins
High-Performance Liquid Chromatography: Elution Process
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...