Quantitative ultrasonic characterization of diffuse scatterers in the presence of structures that produce coherent
Adam C Luchies1, Goutam Ghoshal, William D O'Brien
1Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, IL, USA. luchies1@illinois.edu
Abstract:
Quantitative ultrasound (QUS) techniques that parameterize the backscattered power spectrum have demonstrated significant promise for ultrasonic tissue characterization. Some QUS parameters, such as the effective scatterer diameter (ESD), require the assumption that the examined medium contains uniform diffuse scatterers. Structures that invalidate this assumption can significantly affect the estimated QUS parameters and decrease performance when classifying disease. In this work, a method was developed to reduce the effects of echoes that invalidate the assumption of diffuse scattering. To accomplish this task, backscattered signal sections containing non-diffuse echoes were identified and removed from the QUS analysis. Parameters estimated from the generalized spectrum (GS) and the Rayleigh SNR parameter were compared for detecting data blocks with non-diffuse echoes. Simulations and experiments were used to evaluate the effectiveness of the method. Experiments consisted of estimating QUS parameters from spontaneous fibroadenomas in rats and from beef liver samples. Results indicated that the method was able to significantly reduce or eliminate the effects of nondiffuse echoes that might exist in the backscattered signal. For example, the average reduction in the relative standard deviation of ESD estimates from simulation, rat fibroadenomas, and beef liver samples were 13%, 30%, and 51%, respectively. The Rayleigh SNR parameter performed best at detecting nondiffuse echoes for the purpose of removing and reducing ESD bias and variance. The method provides a means to improve the diagnostic capabilities of QUS techniques by allowing separate analysis of diffuse and non-diffuse scatterers.
Related Concept Videos
Echo
Imagine the sound is reflected back to the ears. Assuming that the source is very close to the human, the difference between hearing the two sounds—the emitted sound and the reflected sound—may be more than the minimum time for perceiving distinct sounds. If this is the case, then the...
Ultrasonography
During an ultrasonography procedure, a handheld device called a...