Comparison of helical and axial mode indirect computed tomographic venography in patients with pulmonary
Naveen Kalra1, Sameer Vyas, Ashish Gupta
1Department of Radiodiagnosis and Internal Medicine, PGIMER, Chandigarh, Punjab, India.
Objective:
To compare the helical and axial modes of indirect computed tomographic (CT) venography (CTV) for accuracy for diagnosing deep venous thrombosis (DVT) of the lower extremities as well as for their radiation burden in patients proven to have pulmonary thromboembolism (PTE) on CT pulmonary angiography (CTPA).
Subjects And Methods:
Of patients evaluated with CTPA for suspected acute PE, 20 of patients who were found to have PTE underwent both indirect CTV of the lower extremities and color Doppler examination. For indirect CTV, patients were randomly assigned to helical and axial modes. The CTV and Doppler findings were interpreted by two experienced radiologists who were blinded to the results of each other.
Results:
Out of total of 260 venous segments analyzed (130 venous segments each by helical or axial CTV), thrombi were seen in 43 venous segments (15 and 28 each by helical or axial CTV respectively). On comparison with Doppler, helical CTV had 82.35% sensitivity and 99.11% specificity, whereas axial CTV had 96.6% sensitivity and 100% specificity. The mean radiation dose was significantly higher for helical (1153.57 mgy.cm) as compared to axial mode CTV (806.28 mgy.cm) with P value of <0.0001.
Conclusion:
Axial CTV results in decreased radiation dose without significant change in the accuracy, as compared to helical CTV in the evaluation of DVT.
More Related Videos
Related Concept Videos
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care
Venous Thrombosis III: Interprofessional Care