Related Experiment Video
Updated: May 22, 2026

Morphological and Functional Assessment of the Right Ventricle Using 3D Echocardiography
Published on: October 28, 2020
Three-dimensional transesophageal echocardiography for perioperative right ventricular assessment
Joern Karhausen1, Roman Dudaryk, Barbara Phillips-Bute
1Division of Cardiothoracic Anesthesiology and Critical Care Medicine, Department of Anesthesiology, Duke University Medical Center, Durham, North Carolina, USA.
Background:
In high-risk cardiac procedures, dynamic analysis of right ventricular (RV) performance is desirable, but the geometric complexity of the RV limits the applicability of current two-dimensional echocardiographic imaging techniques. This study aimed to evaluate the utility of three-dimensional transesophageal echocardiography (TEE) for the perioperative assessment of RV function and dimensions.
Methods:
Patients undergoing cardiac surgical procedures with complete TEE examinations were identified and reviewed according to current guidelines to exclude patients with significant coexisting valvular regurgitation. Full-volume, three-dimensional datasets were analyzed by two independent investigators using stand-alone software, and left ventricular and RV dimensions were recorded.
Results:
Datasets from 50 patients undergoing cardiac surgical procedures were evaluated for this study. The mean RV volume was 111.7 mL (range, 37.5 to 349.7 mL) at end diastole and 67.6 mL (range, 25.5 to 274.4 mL) at end systole. Intraobserver reliability was 0.93 and 0.90 for end diastolic and 0.77 and 0.87 for end systolic volumes. The interobserver reliability for RV volumes was 0.83 at end diastole and 0.86 at end systole. The mean stroke volume was 43.6 mL (range, 12 to 111.2 mL) for the RV and 49.1 mL (range, 19.9 to 102.8 mL) for the left ventricle; the correlation coefficient between the two was 0.85.
Conclusions:
Three-dimensional TEE volumetric measurements were reproducible across a wide range of RV dimensions. As postulated by the continuity principle, stroke volume measurements between both ventricles correlated well, supporting the validity of this approach. Therefore, our work provides preliminary evidence that three-dimensional TEE offers reproducible information about RV function and size in the dynamic and complex perioperative setting of cardiac surgical procedures.
More Related Videos
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Cardiac Catheterization II: Right Heart Catheterization
Cardiac Catheterization III: Left Heart Catheterization

