Compton spectroscopy for rotation-mode computed tomography
A Mohammadi1, M Baba, M Nakhostin
1Cyclotron and Radioisotope Center, Tohoku University, Sendai, Japan. akram@cyric.tohoku.ac.jp
Abstract:
In computed tomography (CT) systems, it is desirable to know the X-ray energy spectra for various applications, including medical CT imaging, and diagnostic field and heavy ion therapy. However, because of the restricted space, the only practical solution is to use Compton spectroscopy, where the incident spectrum is inferred from the scattered spectrum. The geometry of the scatterer and its position within the CT can affect the spectrum of the secondary beam, making it difficult to determine the primary spectrum during operation of the CT system. A modified Compton spectrometer is described that allows measurement of the X-ray energy spectra during operation, and most importantly, in rotation mode. The geometry of the scatterer was optimized to reduce the energy broadening of the secondary beam. The performance of the system was evaluated by comparing the reconstructed exposure to that measured directly using an ion chamber.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Imaging Studies III: Computed Tomography
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
2D NMR: Homonuclear Correlation Spectroscopy (COSY)