Protocol for Relative Hydrodynamic Assessment of Tri-leaflet Polymer Valves
Published on: October 17, 2013
Comparison of two spike areas in bileaflet mechanical valve closing sound
Hiroshi Sugiki1, Suguru Kubota, Yoshiro Matsui
1Department of Cardiovascular Surgery, Hokkaido University Postgraduate School of Medicine, North-14, West-5, Kita-Ku, Sapporo, 060-8848, Japan. hsugiki@aol.com
Abstract:
We previously reported our development of a wavelet analysis system which demonstrates that in vivo bileaflet mechanical valve sound splits into two spikes at higher frequency levels and, based on this system, proposed criteria for detecting malfunctioning bileaflet valves (MBVs). However, the results of that study were only tentative due to the small number of patients with MBVs enrolled in the study. Here, we discuss the possibility of new criteria based on the scalographic properties of two spikes of bileaflet valve sound. The study cohort comprised 12 patients who each received a Carbomedics valve. Based on cinefluoroscopy findings, seven valves were classified into a "normal" group, and the other five were classified into a "malfunction" group. Five consecutive valve sounds for each valve were collected for the wavelet analysis in order to re-evaluate the previously proposed criteria and to measure both anterior spike area (Aa) and posterior spike area (Pa) for calculating the spike area ratio (Aa/Pa). The proposed criteria, namely, a single spike or coefficient of variation of <0.1120 detected only two of the five malfunctioning valves, as well as one normal valve to be malfunctioning. The mean Aa/Pa of all malfunctioning valves [2.45 ± 0.63; 95 % confidence interval (CI) ±1.01, 95 % confidence limits (CL) 1.44-3.46] was significantly higher than that of all normal valves (1.17 ± 0.27; 95 % CI ±0.25, 95 % CL 0.92-1.42). Based on this result, we determined the cutoff value of Aa/Pa to be 1.4. The combination of a single spike on the scalogram and an Aa/Pa of >1.4 detected more MBVs than previously proposed criteria. This combination may represent new criteria for detecting MBVs.
Related Concept Videos
Heart Sounds
Auscultation is the process of listening to these internal body sounds using a stethoscope. The heart produces four types of sounds, but only two—S1 and S2—can usually be heard with a stethoscope.
S1, also known as the "lub" sound, is caused by the closure of atrioventricular (A-V) valves at the...
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Korotkoff Sounds
During blood pressure assessment, inflating the cuff 30 millimeters of mercury above the patient's systolic blood pressure...
Cardiovascular System Abnormal Findings II: Auscultation
Abnormal Heart Sounds
Gallops:
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.