Sensitivity analysis of some critical factors affecting simulated intrusion volumes during a low pressure transient event in a full-scale water distribution system
Related Experiment Video
Updated: May 21, 2026

Study of Siphon Breaker Experiment and Simulation for a Research Reactor
Published on: September 26, 2017
G Ebacher1, M C Besner, B Clément
1École Polytechnique de Montréal, NSERC Industrial Chair on Drinking Water, Civil, Geological and Mining Engineering, CP 6079, Succ. centre-ville, Montréal, QC, H3C 3A7 Canada. gabrielle.ebacher@polymtl.ca
Abstract:
Intrusion events caused by transient low pressures may result in the contamination of a water distribution system (DS). This work aims at estimating the range of potential intrusion volumes that could result from a real downsurge event caused by a momentary pump shutdown. A model calibrated with transient low pressure recordings was used to simulate total intrusion volumes through leakage orifices and submerged air vacuum valves (AVVs). Four critical factors influencing intrusion volumes were varied: the external head of (untreated) water on leakage orifices, the external head of (untreated) water on submerged air vacuum valves, the leakage rate, and the diameter of AVVs' outlet orifice (represented by a multiplicative factor). Leakage orifices' head and AVVs' orifice head levels were assessed through fieldwork. Two sets of runs were generated as part of two statistically designed experiments. A first set of 81 runs was based on a complete factorial design in which each factor was varied over 3 levels. A second set of 40 runs was based on a latin hypercube design, better suited for experimental runs on a computer model. The simulations were conducted using commercially available transient analysis software. Responses, measured by total intrusion volumes, ranged from 10 to 366 L. A second degree polynomial was used to analyze the total intrusion volumes. Sensitivity analyses of both designs revealed that the relationship between the total intrusion volume and the four contributing factors is not monotonic, with the AVVs' orifice head being the most influential factor. When intrusion through both pathways occurs concurrently, interactions between the intrusion flows through leakage orifices and submerged AVVs influence intrusion volumes. When only intrusion through leakage orifices is considered, the total intrusion volume is more largely influenced by the leakage rate than by the leakage orifices' head. The latter mainly impacts the extent of the area affected by intrusion.
More Related Videos
07:21Measurements of Soil Water Potential and Conductivity based on a Simple Evaporation Experiment using a Hydraulic Property Analyzer
Published on: August 9, 2024
07:14Tracking Infiltration Front Depth Using Time-lapse Multi-offset Gathers Collected with Array Antenna Ground Penetrating Radar
Published on: May 1, 2018
Related Concept Videos
Design Example: Designing a Residential Plumbing System
Design Example: Creating a Hydraulic Model of a Dam Spillway
Single Pipe Systems
In a Type I problem, fluid properties (density and viscosity), pipe characteristics (including diameter, length, and surface roughness), and the flow rate or average velocity are known. The...
Typical Model Studies
Design Example: Analyzing Capacity Contours for Flood Risk Assessment
Indefinite Integrals