Updated: May 21, 2026

Measurement of Dynamic Scapular Kinematics Using an Acromion Marker Cluster to Minimize Skin Movement Artifact
10:07

Measurement of Dynamic Scapular Kinematics Using an Acromion Marker Cluster to Minimize Skin Movement Artifact

Published on: February 10, 2015

Measuring the Cobb angle with the iPhone in kyphoses: a reliability study.

Frederic Jacquot1, Axelle Charpentier, Sofiane Khelifi

  • 1Orthopedics, Hôpital Saint Antoine, Paris, France. frederic.jacquot@sat.aphp.fr

International Orthopaedics
|June 2, 2012
PubMed
Summary

An iPhone application reliably measures kyphotic angles, showing excellent correlation with the standard protractor method. This smartphone tool offers a valid and reproducible alternative for assessing spinal deformities.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

CT scan-based measurement technique to assess axial torsion of forearm bones.

The Journal of hand surgery, European volume·2025
Same author

Vascularized rib graft for proximal scaphoid reconstruction: An anatomical study.

Hand surgery & rehabilitation·2025
Same author

Evaluation of intravenous tranexamic acid in total hip arthroplasty for femoral neck fracture: A propensity score-matched, real-world analysis.

Orthopaedics & traumatology, surgery & research : OTSR·2025
Same author

Hidden costs of surgical complications: a retrospective cohort study.

BMJ surgery, interventions, & health technologies·2025
Same author

The sub pronator approach to the coronoid process.

Orthopaedics & traumatology, surgery & research : OTSR·2025
Same author

Flexor tendon repair in a socially deprived population: A retrospective cohort study.

Hand surgery & rehabilitation·2025

Area of Science:

  • Orthopedics
  • Medical Imaging
  • Digital Health

Background:

  • Smartphones are increasingly utilized in healthcare for diverse applications.
  • Measuring spinal deformity angles is crucial for diagnosis and treatment planning.

Purpose of the Study:

  • To develop and assess the reliability of an iPhone application for measuring kyphotic angles.
  • To compare the accuracy of the iPhone application against the traditional protractor method.

Main Methods:

  • Radiographs from 20 patients were measured by six operators at two separate times.
  • Measurements were taken using both a protractor and the developed iPhone application (CobbMeter).
  • Intraclass correlation coefficients (ICCs) were calculated to assess inter- and intraobserver reliability and method agreement.

More Related Videos

Subjective Refraction Test Using a Smartphone for Vision Screening
05:36

Subjective Refraction Test Using a Smartphone for Vision Screening

Published on: October 18, 2024

Video Movement Analysis Using Smartphones (ViMAS): A Pilot Study
07:51

Video Movement Analysis Using Smartphones (ViMAS): A Pilot Study

Published on: March 14, 2017

Related Experiment Videos

Last Updated: May 21, 2026

Measurement of Dynamic Scapular Kinematics Using an Acromion Marker Cluster to Minimize Skin Movement Artifact
10:07

Measurement of Dynamic Scapular Kinematics Using an Acromion Marker Cluster to Minimize Skin Movement Artifact

Published on: February 10, 2015

Subjective Refraction Test Using a Smartphone for Vision Screening
05:36

Subjective Refraction Test Using a Smartphone for Vision Screening

Published on: October 18, 2024

Video Movement Analysis Using Smartphones (ViMAS): A Pilot Study
07:51

Video Movement Analysis Using Smartphones (ViMAS): A Pilot Study

Published on: March 14, 2017

Main Results:

  • Excellent correlation (ICC=0.963) was found between the iPhone application and the protractor method.
  • High intraobserver (ICC=0.977) and interobserver (ICC=0.965) reliability were demonstrated for the iPhone application.
  • The iPhone application showed slightly higher, though not statistically significant, reliability compared to the protractor.

Conclusions:

  • The iPhone application is a valid tool for measuring kyphotic angles.
  • This smartphone-based method is comparable in accuracy to the standard protractor technique.
  • The application offers a reliable and reproducible approach for assessing spinal deformities.