Related Experiment Video
Updated: May 21, 2026

Optimized Management of Endovascular Treatment for Acute Ischemic Stroke
Published on: January 18, 2018
Ability of emergency physicians to detect early ischemic changes of acute ischemic stroke on cranial computed
Erden Erol Ünlüer1, Erdem Yaka, Galip Akhan
1Department of Emergency Medicine, Izmir Ataturk Research and Training Hospital, Izmir, Turkey. erolerdenun @ yahoo.com
Objective:
The objective of this study was to evaluate the ability of emergency physicians (EPs) to diagnose early ischemic changes due acute ischemic stroke on cranial computed tomography (CT).
Subjects And Methods:
Three EPs interpreted CT scans obtained within 3 h of symptom onset in 50 patients with acute stroke. The CT scans were interpreted by the EPs and compared to official neuroradiologist reports as a gold standard. ĸ statistics were calculated to determine agreement among the three readers. Sensitivities and specificities were analyzed for each reader.
Results:
The EPs' sensitivities were 50, 45.5, and 45.5%, and specificities were 64.3, 82.1, and 64.3%, respectively. Focal parenchymal hypodensity was the criterion for which the EPs were the most sensitive (77.3%). The ability of EPs to recognize early ischemic changes on CT scans in acute ischemic stroke was moderate based on sensitivities.
Conclusion:
Based on this study, EPs must be trained especially for recognizing early ischemic changes in acute ischemic stroke to improve their accuracy of interpretation.
More Related Videos
13:10Combined Near-infrared Fluorescent Imaging and Micro-computed Tomography for Directly Visualizing Cerebral Thromboemboli
Published on: September 25, 2016
09:52Setting Up a Stroke Team Algorithm and Conducting Simulation-based Training in the Emergency Department - A Practical Guide
Published on: January 15, 2017
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Acute Coronary Syndrome III: Diagnostic Studies