One-dimensional mean computed tomography value evaluation of ground-glass opacity on high-resolution images
Akihiko Kitami1, Yoshito Kamio, Shoko Hayashi
1Respiratory Disease Center, Showa University Northern Yokohama Hospital, Yokohama, Japan. akitami@med.showa-u.ac.jp
Objective:
Differentiation of atypical adenomatous hyperplasia (AAH), bronchioloalveolar carcinoma (BAC), and invasive carcinoma on computed tomography (CT) is useful for determining "follow-up or resection" strategies for lesions displaying ground-glass opacity (GGO). The purpose of this study is to evaluate one-dimensional quantitative CT values of GGO on high-resolution CT (HRCT) images using computer-aided diagnosis.
Methods:
Between April 2001 and March 2010, a total of 44 nodules in 42 patients with pure or mixed GGOs ≤2 cm were retrospectively evaluated. Maximum diameter and one-dimensional mean CT (m-CT) value of the diameter were measured using a computer graphics support system (HOPE/DrABLE-EX, Fujitsu, Tokyo, Japan) that displays a CT density profile across the tumor.
Results:
m-CT values were -682 ± 64 HU (range) for AAH lesions, -544 ± 179 (range) for Type A lesions, -496 ± 147 (range) for Type B lesions, and -371 ± 142 (range) for invasive lesions. AAH lesions had a significantly lower m-CT value than Type B lesions. AAH, Type A, and Type B lesions had significantly lower m-CT values than invasive lesions (p < 0.05). All seven GGO lesions with a maximum diameter ≤1 cm and m-CT value ≤-600 HU were pre-invasive lesions, while 16 of 22 (73 %) cases with maximum diameter >1 cm and m-CT value >-600 HU were invasive lesions.
Conclusion:
Observation may be indicated for GGO lesions with a maximum diameter ≤1 cm and m-CT value ≤-600 HU.