Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Atomic Emission Spectroscopy: Lab01:29

Atomic Emission Spectroscopy: Lab

AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...
Atomic Emission Spectroscopy: Overview01:20

Atomic Emission Spectroscopy: Overview

Atomic emission spectroscopy (AES) is an analytical technique used to determine the elemental composition of a sample by analyzing the light emitted from excited atoms. In AES, atoms in a sample are excited to higher energy levels by thermal energy from high-temperature sources, such as plasma, arcs, or sparks. When these excited atoms return to lower energy states, they emit light at specific wavelengths characteristic of each element. The resulting atomic emission spectrum, which consists of...
Atomic Emission Spectroscopy: Instrumentation01:22

Atomic Emission Spectroscopy: Instrumentation

The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers.  Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.
Atomic Emission Spectroscopy: Interference01:30

Atomic Emission Spectroscopy: Interference

In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...
Data Validation01:15

Data Validation

Method validation is a crucial process in analytical chemistry designed to confirm that a given method consistently produces reliable and high-quality results. This process is essential when a method is applied to different sample matrices or when procedural modifications are made, ensuring that the results meet acceptable standards across various applications.
Key parameters for method validation include:
Atomic Absorption Spectroscopy: Lab01:21

Atomic Absorption Spectroscopy: Lab

For AAS measurements, samples must be introduced as clear solutions, often requiring extensive preliminary treatment to dissolve materials like soils, animal tissues, and minerals. Common methods for sample preparation include treatment with hot mineral acids, wet ashing, combustion in closed containers, high-temperature ashing, or fusion with reagents.
 Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Removal of Superior Maxilla and Preservation of Facial Expression.

International dental journal (Philadelphia, Pa.)·2023
Same author

Cardiometabolic health after first pregnancy: Associations with social determinants of health. A nuMoM2b-HHS study.

American heart journal plus : cardiology research and practice·2023
Same author

Electropermeabilization of nematode eggs for parasite deactivation.

Journal of water, sanitation, and hygiene for development : a journal of the International Water Association·2021
Same author

Stillbirth and fetal anomalies: secondary analysis of a case-control study.

BJOG : an international journal of obstetrics and gynaecology·2020
Same author

Improved blackwater disinfection using potentiodynamic methods with oxidized boron-doped diamond electrodes.

Water research·2018
Same author

Validation of a Test Method for Collection and Analysis of Chloroform Emissions From Stationary Sources.

Journal of the Air & Waste Management Association (1995)·2017
Same journal

Wildland Fires in the US between 2007 and 2018: Characterizing Equity in Exposures and Health Impacts.

Environmental science & technology·2026
Same journal

Profiling Active Low-Abundance Microbes in As/Sb-Contaminated Soils via d-Amino Acid-Based In Situ Labeling.

Environmental science & technology·2026
Same journal

Looking beyond Sorption in GAC Filters: How Extended Contact Times and Functionally Distinct Microbial Biomass Enable Enhanced Micropollutant Biodegradation.

Environmental science & technology·2026
Same journal

Integrating Experiments and Models To Unravel Interactions between Soil Organic Matter and Enhanced Weathering.

Environmental science & technology·2026
Same journal

Role of Advanced Direct Extraction Technologies in Reducing Environmental Impacts of Lithium Production.

Environmental science & technology·2026
Same journal

Comparison of High Spatial Resolution PM<sub>2.5</sub>, PM<sub>10</sub>, and NO<sub>2</sub> Estimates Using a Deep Ensemble Machine Learning Framework in a Low Pollution Setting.

Environmental science & technology·2026
See all related articles

Related Experiment Video

Updated: May 21, 2026

Implementation of Portable Emissions Measurement Systems (PEMS) for the Real-driving Emissions (RDE) Regulation in Europe
09:34

Implementation of Portable Emissions Measurement Systems (PEMS) for the Real-driving Emissions (RDE) Regulation in Europe

Published on: December 4, 2016

Quality assurance for emissions analysis systems

R K Jayanty, C B Parker, C F Decker

    Environmental Science & Technology
    |June 5, 2012
    PubMed
    Summary

    No abstract available in PubMed .

    More Related Videos

    Design and Use of a Full Flow Sampling System (FFS) for the Quantification of Methane Emissions
    08:18

    Design and Use of a Full Flow Sampling System (FFS) for the Quantification of Methane Emissions

    Published on: June 12, 2016

    Split Point Analysis and Uncertainty Quantification of Thermal-Optical Organic/Elemental Carbon Measurements
    10:22

    Split Point Analysis and Uncertainty Quantification of Thermal-Optical Organic/Elemental Carbon Measurements

    Published on: September 7, 2019

    Related Experiment Videos

    Last Updated: May 21, 2026

    Implementation of Portable Emissions Measurement Systems (PEMS) for the Real-driving Emissions (RDE) Regulation in Europe
    09:34

    Implementation of Portable Emissions Measurement Systems (PEMS) for the Real-driving Emissions (RDE) Regulation in Europe

    Published on: December 4, 2016

    Design and Use of a Full Flow Sampling System (FFS) for the Quantification of Methane Emissions
    08:18

    Design and Use of a Full Flow Sampling System (FFS) for the Quantification of Methane Emissions

    Published on: June 12, 2016

    Split Point Analysis and Uncertainty Quantification of Thermal-Optical Organic/Elemental Carbon Measurements
    10:22

    Split Point Analysis and Uncertainty Quantification of Thermal-Optical Organic/Elemental Carbon Measurements

    Published on: September 7, 2019