Prospective comparison of noninvasive, bedside ultrasound methods for assessing central venous pressure
H Uthoff1,2, M Siegemund3, M Aschwanden1
1Angiology, University Hospital, Basel, Switzerland.
Purpose:
To prospectively evaluate the accuracy of noninvasive central venous pressure (CVP) assessment by compression ultrasound of a forearm vein (CUS), inferior vena cava (IVC-C) and internal jugular vein collapsibility (IJV-C) compared to invasive CVP measurement (invCVP) as the gold standard.
Materials And Methods:
CUS, IVC-C and IJV-C were performed in a random sequence in 81 consecutive intensive care patients with simultaneous invCVP monitoring. Examiners were blinded to invCVP and previous examinations.
Results:
Median invCVP was 12.0 mmHg (range 1 - 23). CUS, IVC-C and IJV-C could be obtained in 89 %, 95 % and 100 % of cases, respectively, within a median time of 188 sec [IQR 125; 270], 133 sec [IQR 100; 211] and 60 sec [IQR 50; 109], respectively. The Spearman correlation coefficient between invCVP and CUS, IVC-C, and IJV-C was 0.485 95 %-CI [0.25; 0.65], -0.186 [-0.42; 0.07], and -0.408 [-0.59; -0.18], respectively. The median absolute difference between CUS and invCVP was 3 mmHg [IQR 2; 6.75]. CVP was categorized as low (< 7 mmHg; collapsibility > 0.6), normal (7 - 12 mmHg; collapsibility 0.6 - 0.2) and high (> 12 mmHg; collapsibility < 0.2) as prespecified. The proportions of identical CVP classifications compared to invCVP were 61.4% 95%-CI [49.3%; 72.4%] with CUS, 48.7% [37.4%; 60%] with IVC-C and 51.3% [40.3%; 62.3%] with IJV-C (p > 0.10 for all pair-wise comparisons).
Conclusion:
The overall ability of CUS, IVC-C and IJV-C to assess invCVP was only moderate. CUS seems to be the preferable method if absolute CVP values are needed. IJV-C seems to be the fastest and most easily acquirable method, and thus may be especially valuable in emergency rooms.
Related Concept Videos
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Pre-Procedural Guidelines for Assessing Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...