Related Experiment Video
Updated: May 21, 2026

Using Micro-computed Tomography for the Assessment of Tumor Development and Follow-up of Response to Treatment in a Mouse Model of Lung Cancer
Published on: May 20, 2016
PET/CT in lung cancer: Influence of contrast medium on quantitative and clinical assessment
Florian F Behrendt1, Yavuz Temur, Frederik A Verburg
1Department of Nuclear Medicine, University Hospital, RWTH-Aachen University, Pauwelsstrasse 30, 52074, Aachen, Germany. fbehrendt@ukaachen.de
Objectives:
To evaluate the influence of intravenous contrast medium and different contrast medium phases on attenuation correction, PET image quality and clinical staging in combined PET/CT in patients with a suspicion of lung cancer.
Methods:
Sixty patients with a suspicion of lung cancer were prospectively enrolled for combined (18)F-FDG-PET/CT examination. PET images were reconstructed with non-enhanced and arterial and venous phase contrast CT. Maximum and mean standardised uptake values (SUVmax and SUVmean) and contrast enhancement (HU) were determined in the subclavian vein, ascending aorta, abdominal aorta, inferior vena cava, portal vein, liver and kidney and lung tumour. PET data were evaluated visually for clinical staging and image quality.
Results:
SUVmax was significantly increased between contrast and non-contrast PET/CT at all anatomic sites (all P < 0.001). SUVmax was significantly increased for arterial PET/CT compared to venous PET/CT in the arteries (all P < 0.001). Venous PET/CT resulted in significantly higher SUVmax values compared to arterial PET/CT in the parenchymatous organs (all P < 0.05). Visual clinical evaluation of malignant lesions showed no differences between contrast and non-contrast PET/CT (P = 1.0).
Conclusions:
Contrast enhanced CT is suitable for attenuation correction in combined PET/CT in lung cancer; it affects neither the clinical assessment nor image quality of the PET images.
Key Points:
• Positron emission tomography combined with computed tomography is now a mainstream investigation • There has been debate about whether CT contrast agents affect PET results • Contrast-enhanced CT is satisfactory for attenuation correction in lung cancer PET/CT • Multiphase CT does not affect PET; additional unenhanced CT is unnecessary • For quantitative follow-up PET analysis, an identical PET/CT protocol is required.
More Related Videos
06:51Utilizing 18F-FDG PET/CT Imaging and Quantitative Histology to Measure Dynamic Changes in the Glucose Metabolism in Mouse Models of Lung Cancer
Published on: July 21, 2018
08:05Lung CT Segmentation to Identify Consolidations and Ground Glass Areas for Quantitative Assesment of SARS-CoV Pneumonia
Published on: December 19, 2020
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System V: CT
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies III: Computed Tomography