Neurally adjusted ventilatory assist vs pressure support ventilation for noninvasive ventilation during acute
Pierre-Marie Bertrand1, Emmanuel Futier1, Yannael Coisel2
1Department of Anesthesiology and Critical Care, Estaing Hospital, University Hospital of Clermont-Ferrand, Clermont-Ferrand.
Background:
Patient-ventilator asynchrony is common during noninvasive ventilation (NIV) with pressure support ventilation (PSV). We examined the effect of neurally adjusted ventilatory assist (NAVA) delivered through a facemask on synchronization in patients with acute respiratory failure (ARF).
Methods:
This was a prospective, physiologic, crossover study of 13 patients with ARF (median Pa(O(2))/F(IO(2)), 196 [interquartile range (IQR), 142-225]) given two 30-min trials of NIV with PSV and NAVA in random order. Diaphragm electrical activity (EAdi), neural inspiratory time (T(In)), trigger delay (Td), asynchrony index (AI), arterial blood gas levels, and patient discomfort were recorded.
Results:
There were significantly fewer asynchrony events during NAVA than during PSV (10 [IQR, 5-14] events vs 17 [IQR, 8-24] events, P = .017), and the occurrence of severe asynchrony (AI > 10%) was also less under NAVA (P = .027). Ineffective efforts and delayed cycling were significantly less with NAVA (P < .05 for both). NAVA was also associated with reduced Td (0 [IQR, 0-30] milliseconds vs 90 [IQR, 30-130] milliseconds, P < .001) and inspiratory time in excess (10 [IQR, 0-28] milliseconds vs 125 [IQR, 20-312] milliseconds, P < .001), but T(In) was similar under PSV and NAVA. The EAdi signal to its maximal value was higher during NAVA than during PSV ( P = .017). There were no significant differences in arterial blood gases or patient discomfort under PSV and NAVA.
Conclusion:
In view of specific experimental conditions, our comparison of PSV and NAVA indicated that NAVA significantly reduced severe patient-ventilator asynchrony and resulted in similar improvements in gas exchange during NIV for ARF.
Trial Registry:
ClinicalTrials.gov; No.: NCT01426178; URL: www.clinicaltrials.gov.
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation I: Indication and Settings
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include: