Related Experiment Video
Updated: May 21, 2026

Measurement of Tumor T2* Relaxation Times after Iron Oxide Nanoparticle Administration
Published on: May 19, 2023
Diffusion-weighted MR imaging before and after contrast enhancement with superparamagnetic iron oxide for assessment
Hana Kim1, Jeong-Sik Yu, Dae Jung Kim
1Department of Radiology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea.
Purpose:
The purpose of our study was to validate diffusion-weighted MRI (DWI) before and after superparamagnetic iron oxide (SPIO) injection for assessment of hepatic metastases.
Materials And Methods:
Eighty-six hepatic metastases (size range, 0.3-4.7 cm; mean, 1.5 cm) verified pathologically or by follow-up imaging studies in 22 consecutive patients (17 men and 5 women; 44-83 years; mean age, 60 years) during a 13-month period were enrolled. Hepatic MRI, including DWI (b-factors=50, 400, 800 s/mm²) with breath-holding technique of single-shot spin-echo echo-planar imaging (TR/TE=1000/69 ms, average=2) before and after SPIO administration, were retrospectively reviewed by two independent radiologists with a 5-point scale confidence score for each hepatic lesion on pre-contrast DWI (pre-DWI), SPIO-enhanced DWI (SPIO-DWI), and SPIO-enhanced T2*-weighted imaging (SPIO-T2*wI).
Results:
For all lesions, SPIO-T2*wI showed significantly higher confidence score in the diagnosis of hepatic metastases than pre-contrast or SPIO-DWI regardless of the size of b-factors (p<0.05) with only one exception; using b-factor=50 s/mm², the score of SPIO-T2*wI was still higher than SPIO-DWI but there was no statistical significance given by observer 1 (p=0.730). For the subcentimeter lesions (n=37), SPIO-T2*wI showed the highest score, and using b-factor= 50 or 400 s/mm² SPIO-DWI showed similar confidence scores to SPIO-T2*wI by both observers (p>0.05). Pre-DWI using b-factor=50 sec/mm² was also comparable with SPIO-T2*wI by observer 1 (p=0.060).
Conclusion:
Pre-DWI has a limited value for the assessment of hepatic metastases, however, the repetition of DWI after SPIO injection using small b-factors could complement SPIO-T2*wI, especially for subcentimeter lesions.
Insights
Superparamagnetic iron oxide-enhanced T2*-weighted imaging (SPIO-T2*wI) improves hepatic metastases detection. Repeating diffusion-weighted MRI (DWI) after SPIO injection complements SPIO-T2*wI, especially for small lesions.
Area of Science:
- Radiology
- Medical Imaging
- Oncology
Background:
- Hepatic metastases detection is crucial for patient management.
- Diffusion-weighted MRI (DWI) is an emerging technique for liver lesion characterization.
- Superparamagnetic iron oxide (SPIO) contrast agents can enhance MRI signal.
Purpose of the Study:
- To validate diffusion-weighted MRI (DWI) before and after superparamagnetic iron oxide (SPIO) injection for assessing hepatic metastases.
- To compare the diagnostic confidence of pre-contrast DWI, SPIO-enhanced DWI (SPIO-DWI), and SPIO-enhanced T2*-weighted imaging (SPIO-T2*wI).
Main Methods:
- Retrospective review of hepatic MRI including DWI (b-factors 50, 400, 800 s/mm²) in 22 patients with 86 hepatic metastases.
- Two radiologists assessed lesion confidence using a 5-point scale on pre-DWI, SPIO-DWI, and SPIO-T2*wI.
- Analysis included comparisons across different b-factors and lesion sizes.
Main Results:
- SPIO-T2*wI demonstrated significantly higher diagnostic confidence than pre-DWI and SPIO-DWI for all lesions (p<0.05).
- For subcentimeter lesions, SPIO-T2*wI yielded the highest confidence scores.
- SPIO-DWI with low b-factors (50 or 400 s/mm²) showed comparable confidence to SPIO-T2*wI for subcentimeter lesions.
Conclusions:
- Pre-contrast DWI has limited value in assessing hepatic metastases.
- Repeating DWI after SPIO injection, particularly with low b-factors, can complement SPIO-T2*wI.
- This combined approach is especially beneficial for detecting subcentimeter hepatic metastases.
More Related Videos
Related Concept Videos
Magnetic Resonance Imaging
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System IV: CMRI

