On the many advantages of local-electrode atom probes
T F Kelly1, P P Camus, D J Larson
1Department of Materials Science and Engineering, University of Wisconsin, Madison, WI 53706-1609, USA.
Abstract:
Local extraction electrodes offer several crucial advantages for operation of atom probes. Because of the proximity of the local extraction electrode to the specimen, the electric field produced at the specimen apex by a given voltage is enhanced and the voltage required for field evaporation is reduced. In a voltage-pulsed atom probe, the absolute magnitude of the energy uncertainty is correspondingly reduced. High mass resolution (m/deltam > 1000) may therefore be obtained by accelerating the evaporated ions to a greater total potential after the local extraction electrode. The low extraction voltage may also be pulsed rapidly (100 ps rise time) and at high repetition rates (up to 10(5) pulses per second) using currently available solid-state pulsers. Furthermore, a local electrode and intermediate electrodes may be used as optical elements to control the image magnification. All of these benefits may be applied to any type of atom probe. Local-electrode atom probes (LEAP) should be especially advantageous for developing three-dimensional atom probes with high mass resolution and a large field of view. A sample has been developed that consists of many microtips formed on a planar sample using ion beam mask etching. Microtip samples are especially suited to LEAP. Analysis of electrically insulating samples may also be possible with microtip samples in a LEAP. This combination of features suggests flexible, high speed, high mass resolution atom probes that can work with either conventional needle-shaped specimens or the new style of planar microtip specimens.
More Related Videos
11:33All-electronic Nanosecond-resolved Scanning Tunneling Microscopy: Facilitating the Investigation of Single Dopant Charge Dynamics
Published on: January 19, 2018
12:18Co-localizing Kelvin Probe Force Microscopy with Other Microscopies and Spectroscopies: Selected Applications in Corrosion Characterization of Alloys
Published on: June 27, 2022
Related Concept Videos
Overview of Microscopy Techniques
Atomic Force Microscopy
The AFM Probe
The probe is regarded as the heart of any AFM setup and comprises the...
π Electron Effects on Chemical Shift: Overview
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)
Controlled-Potential Coulometry: Electrolytic Methods
The chosen potential ensures...
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...