Viscoelastic adaptation of tendon graft material to compression: biomechanical quantification of graft
Dominik C Meyer1, Jess G Snedeker, Robert A Weinert-Aplin
1Department of Orthopedics, University of Zürich, Balgrist, Forchstrasse 340, 8008, Zürich, Switzerland.
Purpose:
The tensile viscoelastic behaviour of tendon tissue is of central biomechanical importance and well examined. However, the viscoelastic tendon adaptation to external compression, such as when a tendon graft is fixated with an interference screw, has not been investigated before. Here, we quantify this adaptive behaviour in order to develop a new method to mechanically precondition tendon grafts and to better understand volumetric changes of tendinous tissue. The hypothesis of this study was that under compressive loads, tendon grafts will undergo a temporary volumetric (and therefore diametric) reduction, due to the extrusion of water from the tendon.
Methods:
Compressive testing was performed on a material testing machine and load applied through the use of a custom-made mould, with a semi-circular cross section to accommodate the tendon graft. The effects of different compressive forces on the length, diameter and weight of tendon grafts were measured by calipers and a weighing scale, respectively. Further, different strain rates (1 vs. 10 mm/min) (n = 6, per rate), compression method (steady compression vs. creep) (n = 15 for each method) and different compression durations (1, 5, 10 min) (n = 5 for each duration) were tested to identify the most effective combination to reduce graft size by preserving its macroscopic structure.
Results:
The effect of compression on volume reduction (75 % of initial volume and weight) reached a plateau at 6,000 N on an 8-mm tendon bundle. Length thereby increased by approximately 10 %. Both steady compression and creeping were able to reduce dimensions of the graft; however, creeping was more effective. There was no difference in effect with different durations for compression (p > 0.05) in both methods.
Conclusion:
The viscoelastic behaviour of hamstring tendon grafts under pressure allows preconditioning of the grafts for reduction of volume and diameter and therefore to drill a smaller bone tunnel, retaining more of the original bone. At the same time, the collagen content of the transplant is preserved and a tight fit of the transplant in the bone tunnel achieved.