Chromium isotope fractionation during reduction of Cr(VI) under saturated flow conditions

Julia H Jamieson-Hanes1, Blair D Gibson, Matthew B J Lindsay

  • 1Department of Earth and Environmental Sciences, University of Waterloo, 200 University Ave W, Waterloo, ON N2L 3G1, Canada.

Related Concept Videos

Redox Titration: Other Oxidizing and Reducing Agents01:26

Redox Titration: Other Oxidizing and Reducing Agents

Besides iodine, other oxidizing or reducing agents can serve as titrants in redox titrations. Common oxidizing titrants include KMnO4, cerium(IV), and K2Cr2O7. The choice of oxidizing titrants depends on factors like stability, cost, analyte strength, and reaction rate between the analyte and titrant. KMnO4 is a strong oxidizing titrant that reduces from Mn(VII) to Mn(II) in a highly acidic solution, simultaneously oxidizing the analyte to a higher oxidation state. In this case, KMnO4 acts as a...
Supercritical Fluid Chromatography01:18

Supercritical Fluid Chromatography

Supercritical fluid chromatography (SFC) provides a beneficial substitute for gas chromatography (GC) and liquid chromatography (LC) for certain samples because it merges the top attributes of both techniques. SFC allows the separation and analysis of compounds that GC or LC does not easily manage. These compounds are traditionally nonvolatile or thermally unstable, making GC unsuitable and lacking functional groups required for HPLC analysis.
SFC utilizes a supercritical fluid mobile phase,...
Optimizing Chromatographic Separations01:15

Optimizing Chromatographic Separations

Optimizing chromatographic separations is crucial for obtaining clean separations in a minimum amount of time. Optimization is required for several factors, including kinetic effects related to band broadening, plate height, capacity factor, and separation factor.
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Principles Of Column Chromatography01:13

Principles Of Column Chromatography

The chromatography technique was first invented in 1901 by Michael S. Tswett, a Russian botanist, to separate plant pigments using organic solvents. Further, in 1941, Archer John Porter Martin and R. L. M. Synge modified the technique by packing silica gel into a column. A mixture of amino acids was then separated on the packed column using chloroform and water mixture as the mobile phase. This was the first report on column chromatography. At present, column chromatography is a widely used...
Volatilization01:10

Volatilization

Volatilization gravimetry is an analytical technique that measures the mass lost due to the volatilization of the substance. This technique is used to estimate the amount of volatile material in a sample. To perform this method, heat a known amount of the sample to a high temperature in a crucible or other suitable vessel. The volatile substance in the sample evaporates, and the vapor is completely expelled from the crucible either by heating the sample or bubbling a stream of inert gas through...
Benzene to 1,4-Cyclohexadiene: Birch Reduction Mechanism01:18

Benzene to 1,4-Cyclohexadiene: Birch Reduction Mechanism

Birch reduction uses solvated electrons as reducing agents. The reaction converts benzene to 1,4-cyclohexadiene. The reaction proceeds by the transfer of a single electron to the ring to form a benzene radical anion. This anion is highly basic—it abstracts a proton from the alcohol to form a cyclohexadienyl radical. Another single electron transfer gives the cyclohexadienyl anion. A proton transfer from the alcohol forms 1,4-cyclohexadiene. Since this reduction occurs via radical anion...