Structured Approach to Colonoscopy Technique Optimization: A Single-Center Experience with Novice Endoscopists
Published on: July 11, 2025
Comparison of endoscopic task performance with crossed versus uncrossed straight and curved instruments through a
Roberto Rimonda1, Benjie Tang, Stuart I Brown
1Centro Universitario di Chirurgia Mini-Invasiva, Molinette Hospital, University of Turin, Turin, Italy.
Background:
Despite advancing technology for single-incision minimal access surgery, there have been no reports on the optimal operating setup and the instruments for use through a single port. This study therefore aimed to compare task performance in single-port surgery between crossed and uncrossed instruments (straight and distally coaxially curved).
Methods:
A dedicated trainer box was used to investigate the performance of two tasks (pick-transfer-place and dissection) by 18 surgical residents using two randomly allocated manipulating systems: (1) a conventional, uncrossed manipulation system (UCMS), with surgery through a cone-shaped 40-mm port using coaxially curved or straight instruments subtending a 30° manipulation angle, and (2) a crossed manipulation system (CMS), with surgery through a cylindrical miniport (25 mm) using coaxially curved instruments.
Results:
The pick-transfer-place task performed with the UCMS enabled comparison between straight and curved coaxial instruments and showed that although the participants moved the same number of objects with either type (p = 0.464), they dropped a significantly more objects with straight instruments (1.5 ± 1.33 vs. 0.61 ± 0.85; p = 0.013). The execution of this task with the CMS (curved instruments only) provided a performance (dropped objects and error rates) equal to that obtained by the UCMS with curved instruments (p = 0.521, p = 0.989). The dissection task with the UCMS showed no difference between straight and curved coaxial instruments in dissection accuracy (75.6 vs. 75.5%; p = 0.950) or execution times (258 vs. 302 s; p = 0.367). The performance of this task by the CMS and the UCMS (with curved coaxial instruments) was equivalent with regard to dissection accuracy (p = 0.849) and execution time (p = 0.402).
Conclusions:
Using the UCMS, task performance is better with distally curved coaxial instruments. The CMS (with curved instruments) gives a task performance equivalent to that obtained with UCMS.
More Related Videos
Related Concept Videos
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due to...
Endoscopic Procedures V: ERCP
Patient...
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Urologic Endoscopic Procedure: Cystoscopic Examination
Endoscopic Procedures II: Colonoscopy