Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Filtered Diffusion-Weighted MRI of the Human Cervical Spinal Cord: Feasibility and Application to Traumatic Spinal Cord Injury.

AJNR. American journal of neuroradiology·2021
Same author

Quantitative Susceptibility Mapping after Sports-Related Concussion.

AJNR. American journal of neuroradiology·2018
Same author

Evaluation of Electrophysiological Effects of Melatonin and Alpha Lipoic Acid in Rats with Streptozotocine Induced Diabetic Neuropathy.

Experimental and clinical endocrinology & diabetes : official journal, German Society of Endocrinology [and] German Diabetes Association·2016
Same author

Assessment of the Correlation between Apparent Diffusion Coefficient and Intervertebral Disk Degeneration Using 3 Tesla MRI.

The neuroradiology journal·2013
Same author

Wallenberg Syndrome following neck cracking: a case report.

European journal of physical and rehabilitation medicine·2011
Same author

FMRI study relevant to the Mozart effect: brain areas involved in spatial-temporal reasoning.

Neurological research·2001

Related Experiment Video

Updated: May 21, 2026

Noninvasive In Vivo Small Animal MRI and MRS: Basic Experimental Procedures
12:27

Noninvasive In Vivo Small Animal MRI and MRS: Basic Experimental Procedures

Published on: October 20, 2009

MREIT experiments with 200 µA injected currents: a feasibility study using two reconstruction algorithms, SMM and

V E Arpinar1, M J Hamamura, E Degirmenci

  • 1Department of Neurosurgery, Medical College of Wisconsin, Milwaukee, WI, USA.

Physics in Medicine and Biology
|June 12, 2012
PubMed
Summary

Magnetic Resonance Electrical Impedance Tomography (MREIT) can image conductivity using low currents. The iterative sensitivity matrix method (SMM) with Tikhonov regularization shows promise for clinical applications by tolerating noisy data better than harmonic B(Z).

More Related Videos

Combining a Breath-Synchronized Olfactometer with Brain Simulation to Study the Impact of Odors on Corticospinal Excitability and Effective Connectivity
06:13

Combining a Breath-Synchronized Olfactometer with Brain Simulation to Study the Impact of Odors on Corticospinal Excitability and Effective Connectivity

Published on: January 19, 2024

Performing In Vivo and Ex Vivo Electrical Impedance Myography in Rodents
05:44

Performing In Vivo and Ex Vivo Electrical Impedance Myography in Rodents

Published on: June 8, 2022

Related Experiment Videos

Last Updated: May 21, 2026

Noninvasive In Vivo Small Animal MRI and MRS: Basic Experimental Procedures
12:27

Noninvasive In Vivo Small Animal MRI and MRS: Basic Experimental Procedures

Published on: October 20, 2009

Combining a Breath-Synchronized Olfactometer with Brain Simulation to Study the Impact of Odors on Corticospinal Excitability and Effective Connectivity
06:13

Combining a Breath-Synchronized Olfactometer with Brain Simulation to Study the Impact of Odors on Corticospinal Excitability and Effective Connectivity

Published on: January 19, 2024

Performing In Vivo and Ex Vivo Electrical Impedance Myography in Rodents
05:44

Performing In Vivo and Ex Vivo Electrical Impedance Myography in Rodents

Published on: June 8, 2022

Area of Science:

  • Biomedical Engineering
  • Medical Imaging
  • Electrical Impedance Tomography

Background:

  • Magnetic Resonance Electrical Impedance Tomography (MREIT) images tissue conductivity by applying electrical currents and measuring magnetic flux density via MRI.
  • Current MREIT research is limited to phantoms and animals, with clinical translation hindered by a lack of specific safety standards for current limits.
  • Existing medical instrumentation safety standards (e.g., IEC601) limit auxiliary currents to 100 µA, a level significantly lower than currents used in published MREIT studies.

Purpose of the Study:

  • To investigate the feasibility of MREIT for accurate relative conductivity reconstruction in a simple agarose phantom using low injected currents.
  • To evaluate the performance and noise sensitivity of two MREIT reconstruction algorithms under varying current conditions.

Main Methods:

  • MREIT conductivity imaging was performed on an agarose phantom using a total injected current of 200 µA, resulting in 14.7 µA within the imaging slice.
  • Two reconstruction algorithms were tested: iterative Sensitivity Matrix Method (SMM) with Tikhonov regularization and harmonic B(Z).
  • Algorithm performance was assessed at both low (200 µA) and high (5 mA, 367 µA in slice) current levels to determine noise tolerance.

Main Results:

  • Accurate conductivity imaging was achieved at low current levels (200 µA) using the specified imaging parameters.
  • The iterative SMM with Tikhonov regularization demonstrated greater tolerance to noisy data compared to the harmonic B(Z) algorithm.
  • Reconstruction using iterative SMM with Tikhonov regularization was successful even under high current conditions (5 mA).

Conclusions:

  • MREIT is feasible for conductivity imaging at low current levels, suggesting potential for safer clinical applications.
  • The iterative SMM with Tikhonov regularization is a robust algorithm for MREIT reconstruction, particularly in the presence of noise.
  • Further research into MREIT safety standards is crucial for enabling widespread clinical translation.