Related Experiment Video
Updated: May 21, 2026

Rejection of Fluorescence Background in Resonance and Spontaneous Raman Microspectroscopy
Published on: May 18, 2011
Spectral signatures for the classification of microbial species using Raman spectra
Bobbie-Jo M Webb-Robertson1, Vanessa L Bailey, Sarah J Fansler
1Pacific Northwest National Laboratory, 902 Battelle Blvd, J4-33, Richland, WA 99352, USA. bj@pnl.gov
Abstract:
In general, classification-based methods based on confocal Raman microscopy are focused on targeted studies under which the spectral libraries are collected under controlled instrument parameters, which facilitate analyses via standard multivariate data analysis methods and cross-validation. We develop and compare approaches to transform spectra collected at different spectral ranges and varying levels of resolution into a single lower-dimension spectral signature library. This will result in a more robust analysis method able to accommodate spectra accumulated at different times and conditions. We demonstrate these approaches on a relevant test case; the identification of microbial species from a natural environment. The training data were based on samples prepared for three unique species collected at two time points and the test data consisted of blinded unknowns prepared and analyzed at a later date with different instrument parameters. The results indicate that using reduced dimension representations of the spectral signatures improves classification accuracy over basic alignment protocols. In particular, utilizing the microbial species partial least squares discriminant analysis classifier on the blinded samples based on alignment achieved ~78 % accuracy, while both binning and peak selection approaches yielded 100 % accuracy.
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and the...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
MALDI-TOF Mass Spectrometry
Methods of Classification and Identification
IR Frequency Region: Fingerprint Region
The...
Microbial Classification System