The uptake of an early warning system in an Australian emergency department: a pilot study
Julie Considine1, Elspeth Lucas, Bart Wunderlich
1Deakin University - Northern Health Clinical Partnership, Deakin University, Melbourne, VIC, Australia. julie.considine@deakin.edu.au
Objectives:
To evaluate the uptake of an emergency department early warning system (ED EWS) for recognition of, and response to, clinical deterioration.
Design, Setting And Participants:
A descriptive exploratory study conducted in an urban district hospital in Melbourne, Australia. Systematic sampling was used to identify every 10th patient for whom the ED EWS was activated from May 2009 to May 2011.
Main Outcome Measures:
Patient characteristics, ED system data and ED EWS activation characteristics.
Results:
ED EWS activation occurred in 1.5% of ED patients; 204 patients were included in this pilot study. The median age was 65.1 years (interquartile range [IQR], 47.8-77.5 years), 89.2% of patients were classified as triage category 2 or 3, and 82.4% of patients were seen by medical staff before ED EWS activation. Hypotension (27.7%) and tachycardia (23.7%) were the most common reasons for ED EWS activation. Median duration of clinical instability was 39 minutes (IQR, 5- 129 minutes). Nurses made 93.1% of ED EWS activations. Median time between documenting physiological abnormalities and ED EWS activation was 5 minutes (IQR, 0- 20). Most patients (57.8%) required hospital admission: 4.4% of patients required intensive care unit admission.
Conclusions:
The ED EWS resulted in at least two formal reports of clinical deterioration in ED patients per day, indicating reasonable uptake by clinicians. A greater understanding of clinical deterioration in ED patients is warranted to inform an evidence-based approach to recognition of, and response to, clinical deterioration in ED patients.
More Related Videos
07:31Implementation of a Real-Time Psychosis Risk Detection and Alerting System Based on Electronic Health Records using CogStack
Published on: May 15, 2020
09:52Setting Up a Stroke Team Algorithm and Conducting Simulation-based Training in the Emergency Department - A Practical Guide
Published on: January 15, 2017
Related Concept Videos
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care
Cardiopulmonary Resuscitation III: AED Use