Related Experiment Video
Updated: May 21, 2026

Novel Percutaneous Approach for Deployment of 3D Printed Coronary Stenosis Implants in Swine Models of Ischemic Heart Disease
Published on: February 18, 2020
Fatal delayed coronary artery perforation after coronary stent implantation
Sang-Hoon Kim1, Jae-Youn Moon, Jung-Hoon Sung
1Department of Cardiology, CHA Bundang Medical Center, CHA University, Seongnam, Korea.
Abstract:
Most type I and II perforations are predominately caused by hydrophilic and stiff wires, often presented in the delayed form, and do not require pericardial drainage or surgical interventions. However, we report a type III delayed coronary artery perforation at the site of stent implantation after intervention without any evidence of immediate perforations. To the best of our knowledge, this is the first case report of angiographic documentation and treatment of delayed coronary perforation at the site of stent, presented as a cardiac arrest.