Related Experiment Video
Updated: May 21, 2026

Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
Occupational per-patient radiation dose from a conservative protocol for veterinary (18) F-fluorodeoxyglucose
Nicole E Martinez1, Susan L Kraft, Debra S Gibbons
1Department of Environmental and Radiological Health Sciences, Colorado State University, Fort Collins, CO 80526, USA.
Abstract:
The occupational external radiation dose to human medical personnel from positron emission tomography (PET) radiopharmaceuticals has been documented, but to date no corresponding veterinary staff dose data are available. Electronic personal dosimeters (EPDs) were used in this study to measure the per-patient external radiation doses to veterinary staff using a PET/CT (PET combined with computed tomography) protocol in which the patient radiopharmaceutical dose was injected after anesthetic induction. Radiation doses were recorded for the nuclear medicine technologists, the on-duty anesthesiology technologist, and an occasional observer from 19 veterinary (18) F-fluorodeoxyglucose PET/CT studies. Patient mass range was 2.8 to 61.0 kg (22.3 kg mean) and injected activity averaged 6 MBq kg(-1) . The dose range received by nuclear medicine technologists per procedure was 0-30 μSv (9.1 μSv mean), by anesthetists 1-22 μSv (8.2 μSv mean), and by the observer 0-2 μSv (0.5 μSv mean). In both feline and canine studies, placement of the EPD on staff was a significant predictor of radiation dose. Additional significant predictors of staff radiation dose from canine studies included job position and injected activity. The per-patient occupational radiation doses to veterinary PET/CT technologists were slightly greater than those reported for human nuclear medicine PET/CT technologists, but were comparable to estimated radiation doses for nurses caring for nonambulatory human PET/CT patients. Efforts toward maintaining staff radiation doses as low as reasonably achievable (ALARA) will be important as veterinary PET/CT caseload increases.
More Related Videos
11:09High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET