Large-Scale Multi-Omics Genome-Wide Association Studies (Mo-GWAS): Guidelines for Sample Preparation and Normalization
Published on: July 27, 2021
Systematic ratio normalization of gas chromatography signals for biological sample discrimination and biomarker
Benoist Lehallier1, Jérémy Ratel, Mohamed Hanafi
1INRA, UR 370 QuaPA, MASS laboratory, 63122 Saint-Genès-Champanelle, France.
Abstract:
The present paper introduces a new gas chromatography data processing procedure dubbed systematic ratio normalization (SRN) enabling to improve both sample set discrimination and biomarker identification. SRN consists in (1) calculating, for each sample, all the log-ratios between abundances of chromatography-analyzed compounds, then (2) selecting the log-ratio(s) that best maximize the discrimination between sample-sets. The relevance of SRN was evaluated on two data sets acquired through gas chromatography-mass spectrometry as part of separate studies designed (i) to discriminate source-origins between vegetable oils analyzed via an analytical system exposed to instrument drift (data set 1) and (ii) to discriminate animal feed between meat samples aged for different durations (data set 2). Applying SRN to raw data made it possible to obtain robust discrimination models for the two data sets by enhancing the contribution to the data variance of the factor-of-interest while stabilizing the contribution of the disturbance factor. The most discriminant log-ratios were shown to employ the most relevant biomarkers presenting relative independence of the factor-of-interest as well as co-behavior of the disturbance effects potentially biasing the discrimination, such as instrument drift or sample biochemical changes. SRN can be run a posteriori on any data set, and might be generalizable to most of separating methods.
More Related Videos
10:14Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
14:42Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems
Published on: September 23, 2021
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...