MR T1 and T2 relaxations in cysts and abscesses measured by 1.5 T MRI
U N Yilmaz1, F Yaman, S S Atilgan
1Department of Oral and Maxillofacial Surgery, University of Dicle, Diyarbakır, Turkey. utkunezih@dicle.edu.tr
Objectives:
The main objective of this study was to make a comparison between the relaxation rates in jaw cysts and abscesses. Such a comparison should provide quantitative information for MR image analysis.
Methods:
A phantom containing 20 odontogenic jaw cysts and 11 jaw abscesses was imaged with 1.5 T MR. T(1) measurements were performed by using a mixed sequence of inversion recovery and spin echo, while T(2) measurements were carried out by the Carr-Purcell Meiboom-Gill (CPMG) sequence. Cystic fluids and abscesses were compared statistically.
Results:
In cysts and abscesses, respectively, the mean 1/T(1) was 0.9355 s(-1) and 0.8245 s(-1) and the mean 1/T(2) was 2.4575 s(-1) and 4.7073 s(-1). The 1/T(2) in cysts was very highly significantly different from that in abscesses (p = 0.0001). Both T(1) and T(2) were linearly proportional to material contents. T(2) relaxivities [26.458 ml (g s)(-1) for abscesses and 21.455 ml (g s)(-1) for cysts] were higher than T(1) relaxivities [5.4766 ml (g s)(-1) for abscesses and 10.075 ml (g s)(-1) for cysts].
Discussion:
Present T(2) measurements differentiate cysts from abscesses with a confidence interval of 95%. Because in vivo and in vitro image contrasts are changed by the same parameters, the T(2) findings should present valuable information for in vivo MRI. Hence the significant difference and the relaxivities may provide quantitative information for clinicians and researchers making image analyses.
Conclusion:
T(2) may differentiate cysts from abscesses. The difference in T(2) is related to the material content of samples.
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Atomic Nuclei: Types of Nuclear Relaxation
In spin–lattice or longitudinal relaxation, the excited spins exchange energy with the surrounding lattice as they return to the lower energy level. Among several mechanisms that contribute to spin–lattice relaxation, magnetic dipolar interactions are significant. Here, the excited nucleus transfers energy to a nearby...