Related Experiment Video
Updated: May 21, 2026

Employing the Forced Oscillation Technique for the Assessment of Respiratory Mechanics in Adults
Published on: February 9, 2022
Toward an estimation of the clarinet reed pulse from instrument performance
Tamara Smyth1, Jonathan S Abel
1School of Computing Science, Simon Fraser University, 250-13450 102nd Avenue, Surrey, British Columbia, V3T 0A3, Canada. tamaras@cs.sfu.ca
Abstract:
In this work, a technique is presented for estimating the reed pulse from the pressure signal recorded at the bell of a clarinet during performance. The reed pulse is a term given to the typically periodic sequence of bore input pressure pulses, a signal related to the volume flow through a vibrating reed by the characteristic impedance of the aperture to the bore. The problem is similar to extracting glottal pulse sequence from recorded speech; however, because the glottis and instrument reeds have very different masses and opening areas, the source-filter model used in speech processing is not applicable. Here, the reed instrument is modeled as a pressure-controlled valve coupled to a bi-directional waveguide, with the output pressure approximated as a linear time invariant transformation of the product of reed volume flow and the characteristic impedance of the bore. By noting that pressure waves will make two round trips from the mouthpiece to the bell and back for each reed pulse, yielding a distinct positive and negative lobe in the running autocorrelation period of the recorded signal, the round-trip attenuation experienced by pressure waves in the instrument is estimated and used to invert the implied waveguide, producing reed pulse estimates.
Related Concept Videos
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Physical Assessment of the Respiratory Tract III: Percussion
Percussion in Respiratory Assessment
Percussion evaluates underlying tissue composition with audible and tactile vibrations,...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Pulse
The pulse serves as a clinical indicator...
