Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Atomic Absorption Spectroscopy: Radiation and Light Sources01:13

Atomic Absorption Spectroscopy: Radiation and Light Sources

Atomic absorption spectroscopy (AAS) relies on the Beer-Lambert law, which requires that the radiation source emits a narrow range of wavelengths to match the absorption characteristics of the analyte atom. The primary criteria for choosing an appropriate radiation source in AAS is to provide a precise and intense emission at specific wavelengths that will allow accurate detection of the analyte.
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
Atomic Fluorescence Spectroscopy01:29

Atomic Fluorescence Spectroscopy

Atomic fluorescence spectroscopy (AFS) is an analytical technique that involves the electronic transitions of atoms in a flame, furnace, or plasma being excited by electromagnetic (EM) radiation. When these atoms absorb energy, they become excited and subsequently release energy as they return to their original state. This emitted light, or "fluorescence," is observed at a right angle to the incident beam. Both absorption and emission processes transpire at distinct wavelengths, which are...
Atomic Emission Spectroscopy: Instrumentation01:22

Atomic Emission Spectroscopy: Instrumentation

The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers.  Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.
Atomic Emission Spectroscopy: Lab01:29

Atomic Emission Spectroscopy: Lab

AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...
Atomic Emission Spectroscopy: Overview01:20

Atomic Emission Spectroscopy: Overview

Atomic emission spectroscopy (AES) is an analytical technique used to determine the elemental composition of a sample by analyzing the light emitted from excited atoms. In AES, atoms in a sample are excited to higher energy levels by thermal energy from high-temperature sources, such as plasma, arcs, or sparks. When these excited atoms return to lower energy states, they emit light at specific wavelengths characteristic of each element. The resulting atomic emission spectrum, which consists of...
Electrospray Ionization (ESI) Mass Spectrometry01:12

Electrospray Ionization (ESI) Mass Spectrometry

Higher molecular weight biomolecules are nonvolatile compounds that may decompose before ionizing or vaporizing during mass analysis with conventional electron impact ionization methods. Accordingly, electrospray ionization (ESI) is the favored method for vaporizing and ionizing biomolecules as it circumvents rapid fragmentation and enables the recording of mass signals for the entire biomolecule.
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Tetrahedral frameworks and chains in oP32 CaC<sub>2</sub>O<sub>5</sub> and mP80 CaCO<sub>3</sub> calcium carbonates above 100 GPa.

Communications chemistry·2026
Same author

Inorganic Tricarbonate: High-Pressure Synthesis and Structure of K<sub>2</sub>C<sub>3</sub>O<sub>7</sub>.

Journal of the American Chemical Society·2026
Same author

Stabilization of the [C<sub>2</sub>N<sub>5</sub>]<sup>7-</sup> Anion in Recoverable High-Pressure Eu<sub>4</sub>Fe<sub>0.864(6)</sub>(C<sub>2</sub>N<sub>5</sub>)<sub>2</sub> Pyronitridocarbonate.

Journal of the American Chemical Society·2026
Same author

Compressed MgCl<sub>2</sub> Reveals Multiple Pathways to Cotunnite Structures.

Inorganic chemistry·2026
Same author

High-Pressure Synthesis and Structural Studies of La, Sm, Gd, and Dy Chlorides and Chloride Carbides.

ACS omega·2026
Same author

Phonons in Epitaxial DySi_{2}: From the Bulk to Self-Organized Nanoislands and Nanowires.

Physical review letters·2026

Related Experiment Video

Updated: May 21, 2026

Non-invasive 3D-Visualization with Sub-micron Resolution Using Synchrotron-X-ray-tomography
08:51

Non-invasive 3D-Visualization with Sub-micron Resolution Using Synchrotron-X-ray-tomography

Published on: May 27, 2008

The 57Fe Synchrotron Mössbauer Source at the ESRF.

Vasily Potapkin1, Aleksandr I Chumakov, Gennadii V Smirnov

  • 1European Synchrotron Radiation Facility, BP 220, F-38043 Grenoble, France.

Journal of Synchrotron Radiation
|June 21, 2012
PubMed
Summary

A new (57)Fe Synchrotron Mössbauer Source (SMS) offers highly resonant and polarized gamma radiation for Mössbauer spectroscopy. This advanced source enables rapid data collection, significantly reducing experiment times for materials under extreme conditions.

More Related Videos

Angle-resolved Photoemission Spectroscopy At Ultra-low Temperatures
08:53

Angle-resolved Photoemission Spectroscopy At Ultra-low Temperatures

Published on: October 9, 2012

The Automated Crystallography Pipelines at the EMBL HTX Facility in Grenoble
06:50

The Automated Crystallography Pipelines at the EMBL HTX Facility in Grenoble

Published on: June 5, 2021

Related Experiment Videos

Last Updated: May 21, 2026

Non-invasive 3D-Visualization with Sub-micron Resolution Using Synchrotron-X-ray-tomography
08:51

Non-invasive 3D-Visualization with Sub-micron Resolution Using Synchrotron-X-ray-tomography

Published on: May 27, 2008

Angle-resolved Photoemission Spectroscopy At Ultra-low Temperatures
08:53

Angle-resolved Photoemission Spectroscopy At Ultra-low Temperatures

Published on: October 9, 2012

The Automated Crystallography Pipelines at the EMBL HTX Facility in Grenoble
06:50

The Automated Crystallography Pipelines at the EMBL HTX Facility in Grenoble

Published on: June 5, 2021

Area of Science:

  • Nuclear Physics
  • Materials Science
  • Spectroscopy

Background:

  • Mössbauer spectroscopy traditionally uses radioactive sources, limiting brilliance and resolution.
  • Synchrotron radiation offers a powerful alternative for nuclear resonant applications.

Purpose of the Study:

  • To design and describe a (57)Fe Synchrotron Mössbauer Source (SMS) for enhanced energy-domain Mössbauer spectroscopy.
  • To leverage synchrotron radiation for high-brilliance, polarized, and tunable resonant gamma-ray beams.

Main Methods:

  • Utilizing a nuclear resonant monochromator with pure nuclear reflections from an iron borate ((57)FeBO(3)) crystal.
  • Implementing collimation of incident synchrotron radiation for optimal crystal illumination and energy resolution.

Main Results:

  • The SMS provides tunable (57)Fe resonant radiation (14.4 keV) with a narrow bandwidth (15 neV).
  • Achieved a focused beam spot size of 10 µm × 5 µm with high brilliance and polarization.
  • Demonstrated a significant reduction in data acquisition time, e.g., ~10 min for a high-pressure spectrum vs. >1 week.

Conclusions:

  • The developed SMS is a powerful tool for studying small samples under extreme conditions (high pressure, high temperature, ultrahigh vacuum).
  • Its high intensity, small spot size, and rapid data collection capabilities revolutionize Mössbauer spectroscopy experiments.
  • The SMS is compatible with existing experimental setups and operates without gating, enhancing its versatility.