Related Experiment Video
Updated: May 21, 2026

Measuring Maxillary Posterior Tooth Movement: A Model Assessment using Palatal and Dental Superimposition
Published on: February 23, 2024
Prosthodontic maintenance requirements of implant-retained overdentures using the locator attachment system
Joe Vere1, Derek Hall, Raj Patel
1Charles Clifford Dental Hospital, Sheffield, UK. jwvere@yahoo.co.uk
Abstract:
The aim of this study was to investigate the prosthodontic maintenance requirements of patients rehabilitated with maxillary and mandibular implant-retained overdentures using the Locator Attachment System by retrospectively reviewing case records. Fifty patients made 112 unplanned return visits over a 3-year period. The most common reasons for returning were denture adjustments (n = 45), inadequate retention (n = 39), and loosening of the implant abutments (n = 14). Implant-retained overdentures using the Locator Attachment System have comparable prosthodontic maintenance requirements to other attachment systems. Problems associated with these prostheses are usually simple to resolve chairside.