Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

¹H NMR: Interpreting Distorted and Overlapping Signals01:02

¹H NMR: Interpreting Distorted and Overlapping Signals

Spin systems where the difference in chemical shifts of the coupled nuclei is greater than ten times J are called first-order spin systems. These nuclei are weakly coupled, and their chemical shifts and coupling constant can generally be estimated from the well-separated signals in the spectrum.
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
Double Resonance Techniques: Overview01:12

Double Resonance Techniques: Overview

Double resonance techniques in Nuclear Magnetic Resonance (NMR) spectroscopy involve the simultaneous application of two different frequencies or radiofrequency pulses to manipulate and observe two distinct nuclear spins. One important application of double resonance is spin decoupling, which selectively suppresses coupling with one type of nucleus while observing the NMR signal from another nucleus, simplifying the spectrum and enhancing resolution.
Spin decoupling is usually achieved by...
NMR Spectrometers: Resolution and Error Correction01:14

NMR Spectrometers: Resolution and Error Correction

When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview01:13

Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview

Attenuated total reflectance (ATR) infrared spectroscopy is a powerful analytical technique used to study the composition of materials. It is widely employed in chemistry, materials science, forensic science, and other fields where sample characterization is required. ATR has several advantages over traditional transmission IR spectroscopy, including the requirement of little to no sample preparation and the ability to analyze a wide range of samples.
The ATR process begins by directing a beam...
Spectrophotometry: Introduction01:16

Spectrophotometry: Introduction

Spectrophotometry is the quantitative measurement of the absorption, reflection, diffraction, or transmission of electromagnetic radiation through a material as a function of the intensity and wavelength of the radiation. A spectrophotometer is a device used to measure the change in the radiation intensity caused by its interaction with the material.
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...
Measuring Reaction Rates03:09

Measuring Reaction Rates

Polarimetry finds application in chemical kinetics to measure the concentration and reaction kinetics of optically active substances during a chemical reaction. Optically active substances have the capability of rotating the plane of polarization of linearly polarized light passing through them—a feature called optical rotation. Optical activity is attributed to the molecular structure of substances. Normal monochromatic light is unpolarized and possesses oscillations of the electrical field in...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Analysis of radioactive waste generated during the cyclotron production of <sup>99m</sup>Tc.

Physics in medicine and biology·2019
Same author

Superiorized algorithm for reconstruction of CT images from sparse-view and limited-angle polyenergetic data.

Physics in medicine and biology·2017
Same author

Imaging study of using radiopharmaceuticals labeled with cyclotron-produced <sup>99m</sup>Tc.

Physics in medicine and biology·2016
Same author

Resolution recovery for Compton camera using origin ensemble algorithm.

Medical physics·2016
Same author

Molybdenum target specifications for cyclotron production of 99mTc based on patient dose estimates.

Physics in medicine and biology·2015
Same author

A fast and simple dose-calibrator-based quality control test for the radionuclidic purity of cyclotron-produced (99m)Tc.

Physics in medicine and biology·2015

Related Experiment Video

Updated: May 21, 2026

An Introduction to Processing, Fitting, and Interpreting Transient Absorption Data
08:12

An Introduction to Processing, Fitting, and Interpreting Transient Absorption Data

Published on: February 16, 2024

Effects of attenuation in single slow rotation dynamic SPECT.

T Humphries1, A Celler, M Trummer

  • 1Department of Mathematics, Simon Fraser University, 8888 University Ave, Burnaby, British Columbia, Canada, V5A 1S6. thumphries@mun.ca

Physics in Medicine and Biology
|June 23, 2012
PubMed
Summary

Standard attenuation correction (AC) methods are insufficient for dynamic SPECT imaging, leading to artifacts. This study introduces a new method to eliminate these artifacts, significantly improving image accuracy for dynamic SPECT scans.

More Related Videos

High Speed Sub-GHz Spectrometer for Brillouin Scattering Analysis
13:31

High Speed Sub-GHz Spectrometer for Brillouin Scattering Analysis

Published on: December 22, 2015

Proton Transfer and Protein Conformation Dynamics in Photosensitive Proteins by Time-resolved Step-scan Fourier-transform Infrared Spectroscopy
10:03

Proton Transfer and Protein Conformation Dynamics in Photosensitive Proteins by Time-resolved Step-scan Fourier-transform Infrared Spectroscopy

Published on: June 27, 2014

Related Experiment Videos

Last Updated: May 21, 2026

An Introduction to Processing, Fitting, and Interpreting Transient Absorption Data
08:12

An Introduction to Processing, Fitting, and Interpreting Transient Absorption Data

Published on: February 16, 2024

High Speed Sub-GHz Spectrometer for Brillouin Scattering Analysis
13:31

High Speed Sub-GHz Spectrometer for Brillouin Scattering Analysis

Published on: December 22, 2015

Proton Transfer and Protein Conformation Dynamics in Photosensitive Proteins by Time-resolved Step-scan Fourier-transform Infrared Spectroscopy
10:03

Proton Transfer and Protein Conformation Dynamics in Photosensitive Proteins by Time-resolved Step-scan Fourier-transform Infrared Spectroscopy

Published on: June 27, 2014

Area of Science:

  • Nuclear Medicine
  • Medical Imaging
  • Image Reconstruction

Background:

  • Dynamic imaging using Single Photon Emission Computed Tomography (SPECT) presents reconstruction challenges due to underdetermined problems.
  • Accurate attenuation correction (AC) is crucial for interpreting tracer dynamics and avoiding misinterpretations caused by attenuation effects during camera rotation.

Purpose of the Study:

  • To demonstrate the inadequacy of standard AC methods in dynamic SPECT imaging.
  • To assess and mitigate artifacts arising from insufficient AC in dynamic SPECT.
  • To introduce and validate a novel method for improved AC in dynamic SPECT.

Main Methods:

  • Evaluation of standard SPECT AC methods' limitations in dynamic imaging scenarios.
  • Utilizing realistic 3D dynamic phantom simulations to model and analyze artifacts.
  • Applying the proposed AC method to real-life dynamic renal SPECT data for validation.

Main Results:

  • Standard AC methods introduce significant artifacts in dynamic SPECT reconstructions.
  • The proposed method effectively eliminates artifacts caused by insufficient attenuation correction.
  • Substantial improvements in the accuracy of reconstructed dynamic SPECT images were achieved.

Conclusions:

  • Conventional AC approaches are insufficient for accurate dynamic SPECT imaging.
  • A novel AC method significantly enhances the fidelity of dynamic SPECT reconstructions.
  • The developed technique offers improved diagnostic accuracy for dynamic SPECT studies.