Related Experiment Video
Updated: May 21, 2026

Combined Near-infrared Fluorescent Imaging and Micro-computed Tomography for Directly Visualizing Cerebral Thromboemboli
Published on: September 25, 2016
Thin-slice reconstructions of nonenhanced CT images allow for detection of thrombus in acute stroke
Christian H Riedel1, Julia Zoubie, Stephan Ulmer
1Department of Neuroradiology, UKS-H, Campus Kiel, Arnold-Heller-Str 3, 24105 Kiel, Germany. c.riedel@neurorad.uni-kiel.de.
Background And Purpose:
The purpose of this study was to investigate whether thin-slice image reconstructions of cranial nonenhanced CT scans could be used to significantly increase sensitivity for detecting intraluminal thrombus in patients with acute ischemic stroke due to proximal occlusion of the middle cerebral artery.
Methods:
In a prospective case series, the raw data of nonenhanced CT scans from 54 patients presenting with acute ischemic stroke and proven vascular obliteration of the middle cerebral artery were collected along with the same data from patients not having a stroke but the same sex and age. All raw data were reconstructed with a slice thickness of 5 mm and as thin slices with a thickness of 0.625 mm. Three observers independently evaluated the 5-mm nonenhanced CT reconstructions and 5-mm maximum intensity projections of the thin slices and rated the likelihood of a clot obliterating the middle cerebral artery trunk or first-order branches using a 5-point scale. The results were evaluated in comparison with base data using receiver operating curve analysis. Interobserver agreement was measured using Cohen κ for every pair of observers.
Results:
The area under the curve for the receiver operating curve analysis for the thick slices ranged from 0.63 to 0.67, whereas for the maximum intensity projection images of the thin slice reconstructions, receiver operating curve analysis revealed areas under the curve between 0.94 and 0.97. Interobserver agreement was higher for thin-slice (κ, 0.69-0.83) versus thick-slice nonenhanced CT reconstructions (κ, 0.38-0.45).
Conclusions:
Thin-slice reconstructions of standard cranial nonenhanced CT raw data allow for more sensitive and reliable detection of clots occluding the proximal middle cerebral artery.
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies